40/64 Assembly
Bosch Rexroth AG
, Accumulator shut-off block type ABZSS, 0532VAW, RE 50129-B/02.19
7 Assembly
Prior to assembly, make sure the following documents are at hand:
• Hydraulic circuit diagram and electric circuit diagram of the machine/system
(available from the machine/system manufacturer)
• Accumulator shut-off block data sheet (contains the admissible technical data)
7.1 Unpacking
CAUTION
Parts falling out!
Risk of injury! Damage to property!
▶
Position the packaged accumulator shut-off block on a level bearing surface.
▶
Only open the packaging from the top.
The accumulator shut-off block is delivered with protective packaging.
▶
Dispose of the packaging in accordance with the national regulations of your
country.
7.2 Installation conditions
The accumulator shut-off block and the attached hydraulic accumulator must be
sufficiently secured and fixed due to their heavy own weight and the acceleration
forces generated by the hydraulic fluid in the hydraulic accumulator.
The hydraulic accumulator is to be fixed in such a way that a safe support during
operational vibrations or in case of a potential pipeline break is guaranteed. The
accumulator manufacturer offers suitable holding devices in the form of mounting
clamps and consoles as accessories.
The installation position of the accumulator shut-off block is based on the
installation position of the hydraulic accumulator. The hydraulic accumulator should
preferably be installed vertically.
Mounting
Installation position