Figure 6.11: Sample application of a control input and use of 2 digital input signals
Control output
CONTROL OUT
Control outputs
The freely programmable control outputs are designed as open collector outputs that have a
high resistance (open) when not active (OFF/inactive). When active (ON/active), the outputs
are closed to ground.
!
Caution!
The maximum permissible current per output is 40 mA. The maximum permissible voltage is
32 V.
To operate externally connected elements, a voltage source is available on the connection V
(the voltage at connection V is identical to the device input voltage); see also the following
illustration. The ground pin is equipped with a common self resettable 750 mA fuse.