14
en | Installation
Power Supply
AR18-10-B002 | v1.1 | 2011.10
Installation manual
Bosch Security Systems
2.4
Connecting the input cable
Figure 2.3
Connecting the input cable
Connect input supply cable as follows:
–
Cut back the insulation of the cable wires to approximately
5 mm (0.2 in).
–
Pass the input cable through the supplied grommet.
–
For each wire, push back the tab behind the terminal with
a small screwdriver and insert the wire (respect the
polarity shown in the figure); release the tab to clamp the
wire in place.
–
Secure the grommet firmly.
–
Return the protective cover to its position and fasten in
place with the four cross-head screws.
Note:
Tighten screws firmly to ensure protection against water
ingress.
5 mm
(0.2 in)
Input
110-230 VAC
50/60 Hz
Earth In
Neutral In
Live In