DANGEROUS ELECTRICAL VOLTAGE
Danger of life through insufficient protective conductor system!
The thyristor power units must be connected to the protective earth-
ing (PE) circuit of the system. Please ensure that the cross-sectional
area of cables used for protective conductor wiring is sufficiently
large. The electrical continuity of the protective earthing circuit must
be verified in accordance with EN 60204 Part 1.
DANGEROUS ELECTRICAL VOLTAGE
Thyristor power units may be operated in earth neutral systems only.
Protective grounding is the only protective measure permitted as per
EN 50 178 (DIN VDE 0160)!
DANGEROUS ELECTRICAL VOLTAGE
Operation in unbalanced networks (only one network phase
grounded) is not permitted.
.
Note: It is recommended that the whole welding system be operated
within a separate welding power network.
CAUTION
Connecting lines and signal lines must be laid so as to avoid nega-
tive effects on the function of the units through capacitive or induc-
tive interference!
Interference is frequently coupled and de-coupled in long cables.
Therefore, thyristor power unit cables and control cables must be
routed separately. The influence of interfering cables on cables sus-
ceptible to interference can be minimized by keeping the following
distances:
D
> 100 mm if cables are run in parallel for < 10 m,
D
> 250 mm if cables are run in parallel for > 10 m.
The thyristor power unit should be mounted close to the welding
systems so as to avoid cable lengths of more than 25 m.
CAUTION
Connection cables may come off and apply dangerous voltage to
system components!
It is crucial that cables are properly fixed.
Summary of Contents for PST 6000 Series
Page 4: ......
Page 28: ...Notes on Rating 3 2 1070 080 058 101 2001 04 GB Notes ...
Page 30: ...Commissioning 4 2 1070 080 058 101 2001 04 GB Notes ...
Page 34: ...Malfunction 6 2 1070 080 058 101 2001 04 GB Notes ...
Page 36: ...Type overview 7 2 1070 080 058 101 2001 04 GB Notes ...
Page 57: ...CE declaration of conformity 10 1 1070 080 058 101 2001 04 GB 10 CE declaration of conformity ...
Page 58: ...CE declaration of conformity 10 2 1070 080 058 101 2001 04 GB Notes ...
Page 62: ...Annex A 4 1070 080 058 101 2001 04 GB ...
Page 63: ...A 1 1070 080 058 101 2001 04 GB 1070 080 058 101 2001 04 GB TI WS AT VWS Printed in Germany ...