Bosch Security Systems | 2011-02
Praesideo 3.5
| Installation and User Instructions | 3 | Control Equipment
en
| 96
5.6
Configuration and operation
5.6.1
Introduction
The next sections give descriptions of the possible
configuration options. Each description is followed by
the relevant menu items with detailed instructions per
menu option. The default values are indicated by an
asterisk (*) when applicable.
5.6.2
Start-up
When the network controller is (re)started, the display
shows the name of the unit and the clock (first of the
status screens).
5.6.3
Status screens
The status screens (see table 5.7) provide general
information about the network controller.
5.6.4
Emergency menu
The
Emergency ...
item (see figure 5.12) provides access to
the emergency menu. This menu is automatically
activated when the system is put into the emergency
state. It changes automatically back to the
Clock
screen
when the emergency state is reset. The
Emergency ...
menu screen itself shows the name of key that was used
to activate the emergency state or the IP address of the
open interface controller that activated the emergency
state. For example:
In this example,
Emergency
indicates that the emergency
state is active and that it was activated by button
CST-EM-PTT
.
The menu items in the emergency menu provide
additional information about the emergency state and
allow to acknowledge and reset the emergency state (see
table 5.8). When the emergency state is reset, all
emergency calls are aborted.
5.6.5
Faults menu
The
Faults ...
menu (see figure 5.12) provides access to
the faults menu. This menu is automatically activated
when there is a fault in the system. Because the number
of active faults in the system can vary, the item numbers
in this menu are not fixed. The youngest fault is the fault
with the lowest number. The maximum number of
faults is 200.
table 5.7: Status screens
Menu item
Description
Clock
Shows the name of the unit and
the time and date.
VU Meter
Visual indication of the signal
strengths on all audio inputs and
audio outputs of the network
controller.
Emergency ...
CST-EM-PTT
table 5.8: Emergency menu
Menu item
Description
1 Date/Time
Date and time on which the
emergency state was activated.
2 Acknowledge
Acknowledges the emergency
state.
3 Reset
Resets the emergency state.
Note
When a new fault occurs while another fault is
being viewed, the item number of the fault that
is being viewed is automatically incremented.
For example, when
23 Overload
is being viewed
while a new fault occurs, it becomes
automatically
24 Overload
.
Note
When fault
200
is being viewed while a new
fault occurs, fault
200
is automatically deleted
and replaced by the next fault. For example,
fault
200
is
200 Overload
and the next fault is
199 Gnd Short
. Then
200 Overload
automatically becomes
200 Gnd Short
when a
new fault occurs.