576414 | REV. B | 28.10.2016
Bosch Automotive Service Solutions Inc.
Power Xpress™ Dual Bollard Charge Station Installation Guide
|
7
|
en
in. The bollard height will vary with the application.
CAUTION: Read all instructions before
installing the EVSE.
WARNING: Main service power must be
off and disconnected before attempting to
install the EVSE.
WARNING: The bollard weighs 20 lb per
foot, and the bottom end is significantly
heavier than the top end. Take proper
precautions and use safe lifting practices
when lifting the bollard.
5. Place the bollard where it is to be installed and drill
holes.
6. Install the 3/4 in. anchor bolts in accordance with
industry standards for the type of mounting being
performed.
NOTE: Adapters may be used to attach junction
box to stand pipe. All adapters and boxes
must be suitable for wet locations.
NOTE: Consult national and local codes for ap-
proved service codes.
7. Adjust charging cable strain relief to the following
locations.
- Top unit - 7 in. from EVSE
- Bottom unit - 24 in. from EVSE