576414 | REV. B | 28.10.2016
Bosch Automotive Service Solutions Inc.
Power Xpress™ Dual Bollard Charge Station Installation Guide
|
15
|
en
- No illumination
- Solid illumination
- Flashing illumination
10.0 Troubleshooting
If there is a charging issue proceed with the following
steps. If the issue persists after three attempts call Bosch
at 1-877-805-EVSE (3873) for assistance.
Problem
Indicated
by LED
Status
Solution
Pilot charg-
ing error
1. Verify supply-side power. The green
POWER LED should be on. If green
POWER LED is off, locate load
center/panel and reset breaker.
2. Press the master clear RESET button
on the front panel of the Charge
Station to attempt a charge-restart.
3. If the red STATUS LED remains
on, disconnect the Charge Station
coupler from the vehicle charge port,
wait 10 seconds, and reconnect the
coupler.
Ground
fault
detected
1. Disconnect main service power at
service panel.
2. Disconnect the Charge Station
coupler from the vehicle.
3. Inspect the Charge Station
connector and the vehicle charge
port verifying both are clean and
undamaged. If vehicle charge port
needs cleaning, follow manufacturer
instructions for cleaning. Clean
Charge Station connector with a dry
or damp cloth if necessary.
4. Restore main service power.
5. Reconnect the coupler to the vehicle
port.
Ground
monitor
interrupted
1. Disconnect main service power at
service panel.
2. Disconnect the Charge Station
coupler from the vehicle.
3. Inspect the Charge Station
connector and the vehicle charge
port verifying both are clean and
undamaged. If vehicle charge port
needs cleaning, follow manufacturer
instructions for cleaning. Clean
Charge Station connector with a dry
or damp cloth if necessary.
4. Restore main service power.
5. Reconnect the coupler to the vehicle
port.