Countertop Requirements
Figure 2 - Cutout Dimensions
Gas Requirements -
Supply Pressure
•
Natural Gas
- 6 inches water column (14.9 Millibars) minimum.
•
Propane Gas
-11 inches water column (27.4 Millibars) minimum.
Propane Gas Installation
(NGT Models only)
NOTE:
NGP models cannot be converted for propane use.
The propane gas tank must be equipped with its own high pressure regulator in
addition to the pressure regulator supplied with this unit. The cooktop is shipped
from the factory for use with natural gas. For use with LP, a conversion kit is
required and must be purchased separately. Contact BSH or your retailer to obtain
kit # NEZ1065. A qualified technician or installer must do the conversion.
Leak testing of the appliance shall be conducted according to manufacturerís
instructions.
4” (101.6mm) Below Countertop
21” (533.4 mm) cooktop depth
Side Wall
7-3/8”(187.8 mm)
Min. to Counter
1/8” (3.5mm)
6” (152.4mm) Min
Combustible Wall
Right Side Wall
3” (76.2 mm) Min. to
1-3/4” (44.5 mm) Min. to
to Left Side Wall
Min Clearance
from Cooktop to
2 1/4” (57.2mm)
Start of Radius
Left Side Wall
4 3/8” (111.6mm)
to Back Wall
3” (76.2 mm) Min.
Min. to Right
Min. to
Front
Table 1: Cutout Dimensions
Fig. 2
30” Models
36” Models
A - Cutout
19-1/8” to 19-7/8”
(486.1mm) to
(505.6mm)
19-1/8 to 19-7/8”
(486.1mm) to
(505.6mm)
B - Cutout
28-5/8” to 29-3/8”
(727.2mm) to
(746.6mm)
34-5/8” to 35-5/8”
(879.6mm) to (899mm)
C - Corner
30” (762mm)
36” (914.4mm)
D - Overall
31” (787.4mm)
37” (939.8mm)