Installation Instructions
Models: NEM73, NEM93
NEM73
B
19
-7
/
8
" / (505 mm)
20" / (508 mm)
C
28
-3
/
4
" / (731 mm)
28
-7
/
8
" / (734 mm)
NEM93
B
19
-7
/
8
" / (505 mm)
20" / (508 mm)
C
34
-3
/
4
" / (883 mm)
34
-7
/
8
" / (886 mm)
PAGE 2
A
B
Overall Dimensions
Model NEM73: Width 30"
Model NEM93: Width 36"
All Models: Depth 21-1/8"
Height above countertop: 1/4"
Model NEM73: 30 Amp circuit breaker
Model NEM93: 40 Amp circuit breaker
All Models
}
240 Volt, 3 Wire, 60 Hz
208 Volt, 3 Wire, 60 Hz
Required Power Supply
Cabinet Bottom
(Unprotected)
Building Back
Wall
Building Side
Wall
Cooking Surface
30" Min.
(762 mm)
"J" Box
12" APPROXIMATE
Conduit
(Approx. 3 feet)
*For solid surface countertop installations, use maximum cutout dimensions and
consult surface manufacturer for specific cutting instructions.
CUTOUT
MODEL NO.
DIM.
DIMENSIONS*
Minimum
Maximum
Inches / (mm)
Inches / (mm)
C
Minimum Cabinet Clearances
D
Junction Box Location
E
Counter Top Cutout Dimensions
B
1" Flat Area
1" Flat Area
1" Flat Area
C
30" Minumum
2-1/2"
Setback Distance
(
from front edge of counter-
top to front edge of cutout.)
1-3/4" Flat Area