TRANSFORMER
(115/230VAC
MODELS)
P101
1 2 3
6 5 4 3 2 1
6 5 4 3 2 1
P106
XF102
XF103
XF101
J103
J102
J101
(LED)
P1
0
7
5
4
3
2 1
GND TXD
RXD
C+
C-
P105
GND TXD
RXD
C+
C-
HTR DOME
(FUSE)
(FUS
E)
(FUS
E)
(FUS
E)
(FUSE)(FUSE)
(FUS
E)
(FUS
E)
(FUS
E)
(FUS
E)
(FUSE)
(FUSE)
(FUSE)
(FUSE)
(FUSE)(FUSE)
(FUSE)
(FUSE)
(FUSE)
LINE NC NEUT
Overview of connections in the unit
1
Ground Screw
7
P101 Connector; Power in (120 VAC / 220
VAC)
2
Not used
8
P106 Connector; not used
3
In/Out; 15 mm (1/2 inch) NPS
Fitting
9
P105 Connector; not used
4
Ethernet connector
10 Left conduit fitting. Use for power wires
20 mm (3/4 inch) NPS Fitting
5
P107 Connector; 24 VAC to camera 11 Right conduit fitting. Use for video, control
and alarm wires; 20 mm (3/4 inch) NPS Fitting
6
In/Out; 15 mm (1/2 inch) NPS
Fitting
Fuse Specifications
Volts
XF101 Mains
XF102 Camera XF103 Heater
24 V
T 5.0 A
T 2.0 A
T 3.15 A
115 V
T 1.6 A
T 2.0 A
T 3.15 A
230 V
T 0.8A
T 2.0 A
T 3.15 A