Mounting the Surveillance cabinet
Before you mount the unit, decide if you route the wires through the holes in the bottom or in
the back of the unit. If you choose the holes in the back, move the 2 seal plugs to the holes in
the bottom before you mount the unit.
Use 20 mm (3/4 inch) NPS fittings for the holes on the bottom and back of the unit. Use 15
mm (1/2-inch) NPS fittings for the side holes.
1.
Use the wall mount template supplied with the unit to locate the 4 mounting holes for the
unit.
2.
Drill holes for the 4 mounting anchors. For outdoor installation, use a weatherproof
sealant around each hole at the mounting surface.
!
Warning!
A stud diameter of 6.4 mm (1/4 inch) to 8 mm (5/16 inch) able to withstand a 120 kg (265 lb)
pull-out force is recommended. The mounting material must be able to withstand this pull out
force. For example, 19 mm (3/4 inch) minimum for plywood.
3.
Place the unit into the optional Trim Skirt.
4.
Mount the unit to the mounting surface.
5.
–
For a Wall installation: Use 4 corrosion-resistant, stainless steel studs (not supplied).
Then proceed to Step 7 below.
–
For a Corner installation: Mount the Corner mount adapter to the wall corner with 4
studs (not supplied). Then proceed to Step 6 below.
–
For a Pole installation: The metal straps included with the Pole mount adapter are
suitable for a pole with a diameter of 100 - 380 mm (4 - 15 inch). Use a banding tool
(not supplied) for a mast or pole installation. Follow the instructions provided with
the banding tool to securely mount the Pole mount adapter to the pole. Contact your
Bosch Sales Representative to order Banding Tool P/N TC9311PM3T.
6.
Mount the unit to the Corner mount adapter or Pole mount adapter with the 4 bolts (3/8
x 1-3/4 inch) and split lock washers (supplied).
7.
Attach 20 mm (3/4 inch) NPS watertight pipe fittings (not supplied) to the bottom or
back holes of the unit for the routing of the power, video, and control data wires.
Routing the wires and attaching the connectors
Making the connections
Refer to illustration for numbers.
1.
Route all video, control, and alarm wires through the conduit fitting on the right side of
the unit (11).
2.
Route the power wires through the conduit fitting on the left side of the unit (10).
3.
Cut and trim the power and ground wires with sufficient slack to reach their connectors
in the unit, but not so long as to be pinched by or to obstruct closing the door. Refer to
the image above for the connector locations.
4.
Attach the supplied 3-pin Power Plug to the incoming power wires. Refer to connector
P101 for wire connections.
5.
Attach an RJ45 plug to the incoming Ethernet cable.