AUTODOME IP starlight 7000i
Status Codes | en
79
Bosch Security Systems
User Manual
2020-07 | v0.7 |
Status
Code
Description
Recommended action
(to be completed by a qualified Service
Technician)
IP fusion 9000i). If the log notes heater or
defroster failure, contact the nearest Bosch
Security Systems Service Center.
3. If operation is obstructed because of
excessive ice buildup, temporarily avoid
operating the pan/tilt functions of the camera
until internal heaters, combined with a rise in
ambient temperature, melt the ice buildup.
18**
When operating using redundant
power sources, the camera has
detected a loss of power from the
external High PoE power source.
1. Verify the operating status of the external
High PoE power source.
2. Verify the integrity of the electrical
connections between the power source and
the camera.
19**
When operating using redundant
power sources, the camera has
detected a loss of power from the
external 24 VAC power source.
1. Verify the operating status of the external
24 VAC power source.
2. Verify the integrity of the electrical
connections between the power source and
the camera.
20
Camera is configured to use the
“Hard Pan Limits” (HPL) feature, and
it has been powered-up with pan
position in the forbidden zone.
Temporarily remove one of the hard pan
limits (as described in
34), pan the camera out of the forbidden
zone, and then restore the hard pan limit.
Reboot the camera by powering the camera
off and then on, or by clicking the button
Reboot
in the camera’s web browser
(
Configuration
>
Camera
>
Installer Menu
>
Reboot device
).
Note
: If pan movement is blocked only in one
direction, but possible in the other direction
(as when the camera is near the HPL), then
no status code appears.
The Hard Pan Limits feature is for MIC cameras only.
Washer and wiper apply to MIC cameras only.
23
An internal error has occurred.
(The optical video screen becomes
blue for 1 or 2 seconds during the
camera’s recovery procedure.)
If this problem begins to occur on a regular
basis:
1. Verify that the power source to the camera
is not experiencing brown-out conditions.
2. Verify that the camera’s earth ground
connection is attached per earlier
instructions.
If these actions do not resolve this problem,
contact the nearest Bosch Security Systems
Service Center.