46 | en
LTC 8600 | LTC 8800 Series
Bosch Security Systems, Inc.
Instruction Manual
F.01U.127.393 | 2.0 | 2009.03
13.2 Monitor Title/System Status Display
The monitor title/system status display area is a 12-column display to the right of
the camera number. It is unique on each of the monitors. It has different uses, some
of which may be selected by the user at a keyboard location. The various uses are
described below.
13.2.1 System Status Display
If this display is selected (factory default), it allows the Allegiant system to dynami-
cally inform the user of the system status. The 12-column display is divided into
smaller message columns (see figure below), in which special characters inform the
user of the following:
•
if the switcher is running or stopped
•
the switcher’s direction
•
if a monitor or remote camera is locked
•
the alarm status of the camera and monitor.
13.2.2 Locations 1, 2, and 3 - Alarm Indication
When the monitor overlay is in the status display mode, locations 1 through 3 indi-
cate if a camera on the monitor is in the alarm mode. If the on-screen camera is cur-
rently in alarm mode, an ALM message will flash in a box at this location mode. If no
cameras are currently in alarm mode on this monitor, these spaces are blank. Note
that when a monitor has cameras in alarm mode, pressing [NEXT], [RUN], or [PRE-
VIOUS] on the keyboard will move you through the alarm sequencer rather than the
regular camera sequencer. The alarm switcher status will be displayed in location 6
using described symbols.
13.2.3 Location 4 - Monitor Arm Status Indication
In the MONITOR ARMED location, the characters SM or DM will appear if the moni-
tor is armed for alarm. SM means that the monitor is a “step” or “sequence” moni-
tor, and will automatically step through multiple alarm videos. DM indicates that the
monitor is a “display” or “review” monitor, which will collect alarm videos from one
or more step monitors.
When an alarm occurs, the alarmed camera's video will replace the current display
of the monitor. If the monitor is not armed, this location will be blank.
13.2.4 Location 5 - Camera Arm Status Indication
In the CAMERA ARMED location characters CA are displayed if the camera being
viewed is armed for alarm on that monitor. If the alarm signal associated with this
camera becomes active, the camera will be displayed on the appropriate armed
monitors.
13.2.5 Location 6 - Error Indication
This location is used to indicate an error on the part of the user. When a user error
occurs, this location will display an ERR symbol. The specific error number will
appear in locations 7 and 8. The error number will also appear in the Camera Num-
ber Display field on the keyboard. The display will return to normal after a few sec-
onds have passed, or if the user presses [Enter] on the keyboard.