background image

LTC 8555 Series | 

Instruction Manual

Installation

EN

| 10

Bosch Security Systems | 29 August 2003

4

DESCRIPTION

The LTC 8555 Series Keyboard is the primary
operator interface to the Allegiant Series of Video
Matrix Switcher/Controllers. These keyboards provide
access to system switching operations, programming,
alarm response, and camera control. Both fixed speed
and variable speed pan/tilt-equipped cameras are easily
operated via the intuitive joystick control. In addition,
simple rotation of the joystick knob allows operators to
control cameras equipped with motorized zoom lenses.  

Easy to read LED displays show real time camera,
monitor, and communication status, as well as error
messages. Keyboards also provide audible and visual
indications of system alarm conditions. A built-in
diagnostic mode makes troubleshooting of suspected
fault conditions easy.

5

INSTALLATION

5.1 General

The maximum number of keyboards that can be
connected to an Allegiant system depends on the
Allegiant model. The following table lists Allegiant
Switcher models and the number of keyboards
supported by each:

Maximum Keyboards

Allegiant

Total

RS-232 Model

Model

Keyboards

Keyboards

LTC 8100 Series

2

2

LTC 8200 Series

4

4

LTC 8300 Series

4

4

LTC 8500 Series

8

8

LTC 8600 Series

16

8

LTC 8800 Series

32

8

LTC 8900 Series

64

4/8

In LTC 8600, and LTC 8900 systems, standard
keyboards above eight are connected to the systems
using either an LTC 8714 Series Keyboard Port
Expander, or a combination of LTC 8714 and 
LTC 8715 Series Keyboard Port Expander accessory
units. Keyboard Port Expander units are Allegiant
accessory devices that are purchased separately. In
LTC 8800 systems, keyboards above eight can be
connected to the LTC 8802 Monitor Expansion bay 
(up to 8 more) and/or Keyboard Port Expanders. 
RS-232 model keyboards are connected to the
Allegiant’s console or printer port or to ports provided
by a LTC 8712 Series Console Expander unit.

When connected directly to an Allegiant CPU bay
using either the supplied cable or the optional 
LTC 8558 Extension Cable, the keyboard is powered
by the Allegiant power supply. In all other
configurations power to the keyboard is typically
provided via a power adapter included in the optional
LTC 8557 Series Remote Hookup kit.

User

Set

Prog

Lock

Alarm

Ack

Monitor

Shot

1

4

7

0

Seq

Run

Next

Prev

Hold

Clear

On

2

5

8

Camera

Off

3

6

9

Focus

Iris

Enter

ALLEGIANT

1

4

7

0

2

5

8

3

6

9

ALLEGIANT

Summary of Contents for LTC 8555

Page 1: ...ty Systems Inc 850 Greenfield Road Lancaster PA 17601 USA Tel 800 326 3270 Fax 1 717 735 6560 www boschsecuritysystems com Bosch Security Systems B V P O Box 80002 5600 JB Eindhoven The Netherlands Tele 31 40 27 80000 Bosch Security Systems Pte Ltd 38C Jalan Pemimpin Singapore 577180 Republic of Singapore Tel 65 6 319 3486 ...

Page 2: ...LTC 8555 Series Instruction Manual EN Allegiant Keyboards ...

Page 3: ...ntended to operate from battery power or other sources refer to the operating instructions 11 Grounding or Polarization This unit may be equipped with a polarized alternating current line plug a plug having one blade wider than the other This plug will fit into the power outlet only one way This is a safety feature If you are unable to insert the plug fully into the outlet try reversing the plug I...

Page 4: ...LTC 8555 Series Instruction Manual EN 31 Bosch Security Systems 29 August 2003 Windows and Windows NT are registered trademarks of Microsoft Corporation ...

Page 5: ...HART Applies to LTC 8555 01 and LTC 8555 03 keyboard models The following chart is used to cross reference the text descriptions contained in the manual with the icons found on keyboard models LTC 8555 01 and LTC 8555 03 Ack Alarm Camera Clear Enter Focus Hold Iris Lock Monitor Next Off On Prev Prog Run Seq Set Shot User ...

Page 6: ...ed for long periods of time unplug it from the wall outlet and disconnect the cable system This will prevent damage to the unit due to lightning and power line surges FCC ICES Information U S A and Canadian Models Only This device complies with part 15 of the FCC Rules Operation is subject to the following two conditions 1 This device may not cause harmful interference and 2 This device must accep...

Page 7: ...ance servicing instructions in the literature accompanying the appliance Sécurité Attention L installation doit être exclusivement effectuée par un technicien spécialisé conformément à la réglementation du code national de l électricité des États Unis NEC ou à la réglementation locale Coupure de l alimentation Les appareils avec ou sans commutateur ON OFF marche arrêt sont alimentés dès que le cor...

Page 8: ... of deflection of the Joystick during pan tilt actions is indicated by a speed indicator value in the first digit position of the LED display Rotation of the Zoom control indicates a value of x41 when rotated clockwise and x40 when rotated counterclockwise Push USER last as this exits the keyboard test mode If the login system features have been selected by the system installer the same local test...

Page 9: ...ting for the operator to dial a phone number and establish communication with the Allegiant a If a key does not seem to be working verify that the attempted function is applicable to the device being controlled or the switcher s current situation b Key or LED may be defective Run the User Function 1 test described in section below a Verify that the attempted function is applicable to the device be...

Page 10: ...kumentation hinweisen die dem Gerät beiliegt Precauciones de Seguridad Atención La instalación debe realizarla personal cualificado en cumplimiento estricto del código eléctrico nacional en el caso de los EE UU o de los códigos locales aplicables Para Desconectar la Alimentación Unidades no equipadas con interruptores ON OFF son alimentadas cuando el cable de alimentación es conectado a la corrien...

Page 11: ...ld om de gebruiker te waarschuwen voor de aanwezigheid van belangrijke bedienings en onderhouds service instructies in de documentatie die met het product zijn meegeleverd Sicurezza Precauzione affidare l installazione al solo personale qualificato e nel rispetto del Codice elettrico nazionale USA o dei codici locali pertinenti Scollegamento dell alimentazione Gli apparecchi con o senza commutator...

Page 12: ... voltage1 2 Gnd 3 Data 4 Data 5 Gnd 6 Supply voltage1 Supplied 6 Pin Data Power Cable Replacement part number 303 0239 001 Side Connection Side 1 Supply voltage1 6 2 Gnd 5 3 Data 4 4 Data 3 5 Gnd 2 6 Supply voltage1 1 Allegiant Console Cable Pinouts part number LTC 8506 00 Allegiant Side Console Port PC Side Serial Port Pin Connection Pin Connection 1 No connection 2 Rx 3 Tx 3 Tx 2 Rx 4 CTS 1 7 CD...

Page 13: ...er of the operator who placed the lock is briefly displayed Refer to the Installation manual supplied with the Allegiant system for a complete listing of error messages applicable to your model system No Function Description Access Level 27 SELECT KEYBOARD LOG IN 12 28 SELECT CONSOLE LOG IN 12 29 RESET RS 232 PARAMETERS 12 30 SELECT CONSOLE RS 232 PARAMETERS except LTC 8900 12 30 SELECT CONTROLLER...

Page 14: ...mação dentro de um triângulo equilátero serve para alertar o utilizador para a presença de instruções de funcionamento e manutenção importantes na documentação fornecida com o aparelho Zasady Bezpieczeństwa Uwaga Instalację urządzenia powinien wykonać tylko wykwalifikowany personel zgodnie z przepisami NEC lub odpowiednimi przepisami miejscowymi Odłączanie zasilania Urządzenia zarówno nie posiadaj...

Page 15: ...OARD CONTROLS 19 6 1 Joystick 19 6 2 Focus and Iris Lens Controls 19 6 3 Numeric Keypad 19 6 4 Star Button 19 6 5 Other Keyboard Buttons 19 6 6 Keyboard Displays 19 7 USER INFORMATION 20 7 1 General 20 7 2 Keyboard Login Procedure 20 7 3 Keyboard Log Off Procedure 20 7 4 Modem Dialing applies to LTC 8555 02 and LTC 8555 03 models only 20 7 5 Keyboard Operating Instructions 21 7 6 Keyboard User Fun...

Page 16: ...nchronized group 7 6 Keyboard User Functions Keyboard User Functions are used to configure system settings that do not require changing on a frequent basis Only operators with a level 1 priority have access to all functions and several require entry of a password A summary list is shown below for complete configuration details refer to the appropriate section of the Allegiant Installation manual C...

Page 17: ...s If a different dwell period for this step is desired change the value to any number between 1 and 60 One line is now complete Press NEXT to add a second line The camera number automatically increments but monitor number and dwell remain the same as the first line Since this line is correct no change is necessary and NEXT may be pressed three more times until line five is reached Note that the jo...

Page 18: ...1 For additional information see www boschsecuritysystems com 3 KEYBOARD MODELS The LTC 8555 Series keyboards are available in four models The table below summarizes the differences between models Model No Top bezel graphics Protocol LTC 8555 00 English text RS 485 LTC 8555 01 Icons RS 485 LTC 8555 02 English text RS 232 LTC 8555 03 Icons RS 232 The LTC 8555 00 and LTC 8555 01 models use the Alleg...

Page 19: ... Allegiant Total RS 232 Model Model Keyboards Keyboards LTC 8100 Series 2 2 LTC 8200 Series 4 4 LTC 8300 Series 4 4 LTC 8500 Series 8 8 LTC 8600 Series 16 8 LTC 8800 Series 32 8 LTC 8900 Series 64 4 8 In LTC 8600 and LTC 8900 systems standard keyboards above eight are connected to the systems using either an LTC 8714 Series Keyboard Port Expander or a combination of LTC 8714 and LTC 8715 Series Ke...

Page 20: ...ror condition If the monitor is in alarm HOLD stops the alarm switcher rather than a loaded sequence 7 5 15 Controlling the Direction of a Sequence The direction of a sequence can be set to run in either a forward or reverse direction It is also possible to manually step though a stopped sequence either forward or reverse These actions work as follows If NEXT is pressed with the sequence in the st...

Page 21: ...f auxiliary 5 When first enabled the pan tilt unit makes one short Left Right cycle to indicate that the DITHER function has been activated Note that a camera in the DITHER mode accumulates a viewing error if left unattended for a long period of time so occasionally a manual adjustment of the pan tilt may be required 7 5 8 Arm disarm Individual Alarms Alarm commands are used to control the system ...

Page 22: ...tible fiber optic link operating at 9600 baud 5 2 LTC 8555 00 and LTC 8555 01 standard keyboard Installation There are several options available for connecting these keyboard models to an Allegiant system The keyboard is supplied with a 3 m 10 ft cable for local hookups as shown in FIGURE 1 Using the optional LTC 8558 00 cable a keyboard can be remoted up to 30 m 100 ft per FIGURE 2 In both of the...

Page 23: ...giant Keyboard Port Allegiant system main CPU bay Optional LTC 8558 00 30 m 100 ft data power cable Allegiant Keyboard Port Allegiant system main CPU bay Up to 1 5 km 5000 ft of user supplied 0 5 mm2 24 AWG shielded twisted pair cable Belden 9841 or equivalent Junction box supplied with LTC 8557 kit Power adapter supplied with LTC 8557 kit 3 m 10 ft data power cable supplied with keyboard Junction...

Page 24: ...from changing the video on the monitor being used Remember to unlock the monitor when finished so that all operators can access it NOTE If an operator with a higher priority accesses a locked monitor and switches to a different camera the lock will automatically be removed 7 5 5 Recording a Camera Pre Position Scene Select a camera with pan tilt zoom control with pre position options as described ...

Page 25: ...splay returns to the flashing dashes mode 9 If the User number and password are valid you will be logged onto the system The keyboard s LEDs now indicate a monitor and camera currently under control by the keyboard EXAMPLE ON 12 ENTER 123456 ENTER This example shows User 12 with password 123456 logging onto the system 7 3 Keyboard Log Off Procedure If the logon feature is not enabled it will not b...

Page 26: ...be connected to an Allegiant switcher When an RS 232 keyboard is connected in the system a standard keyboard port will automatically become disabled The disabled keyboard port number will be based on the interface connection type of the RS 232 keyboard Keeping track of these keyboard numbers is necessary when priority based restrictions or other keyboard related lockouts are assigned and used in t...

Page 27: ...ne Once online with the system an Allegiant prompt appears each time Enter is pressed The prompt will look as follows TC8x00 where x is a digit from one to nine varies based on the Allegiant model being interfaced At the system prompt manually enter the appropriate command based on the Allegiant port in use and type of keyboard interface Refer to the table below to determine the correct command En...

Page 28: ...Focus Near and Iris Open 6 3 Numeric Keypad Use the numeric keypad when it s necessary to enter a numeric value for instance Camera numbers Monitor numbers user number or password information Leading zeros are not necessary when entering a number 6 4 Star Button The key is used to activate an advanced programming feature in the Allegiant CPU It has no default function and will cause ERROR 96 to oc...

Page 29: ...lows NOTE 1 Set this dipswitch to ON to enable handshaking if a modem is connected to the Port Expander and used for communicating to an RS 232 keyboard Because the Port Expander uses this setting for all external connections all external devices connecting to the Port Expander must be configured to operate using a hardware handshake interface Remember to power the Console Port Expander off on whe...

Page 30: ...ails Junction box and power adapter supplied with LTC 8557 kit User supplied female 9 pin D connector 3 m 10 ft data power cable supplied with keyboard User supplied cable or other link suitable for full duplex RS 232 transmissions at 9600 baud Console pin 2 Rx to Tx of link or directly to pin 3 of LTC 8557 box Console pin 3 Tx to Rx of link or directly to pin 2 of LTC 8557 box Console pin 7 Gnd t...

Page 31: ...k A modem interface requires the cable connections below A user supplied cable suitable for RS 232 communications is required Allegiant system main CPU bay CONSOLE port on Allegiant system must be configured for RS 232 Keyboard mode Junction box and power adapter supplied with LTC 8557 kit User supplied Allegiant to modem interface cable User supplied dial up modem link Modem Modem User supplied m...

Page 32: ...e 8 Configuration using LTC 8712 Series Console Port Expander On Allegiant systems with a Printer port up to two Console Port Expanders can be connected supporting a total of eight RS 232 model keyboards To configure an Allegiant system to operate with an LTC 8712 Console Port Expander you must have access to the Allegiant CPU s dipswitches the PC based LTC 8059 Master Control Software and possibl...

Reviews: