4.6.5

N (Network) Suffix Connections

These models include an IP-based camera that enables network 
video and configuration capabilities. 
1.

Make all power connections in accordance with the KBE 
and KBN Series 

Instruction Manual

2.

Connect the camera to a 10/100 Base-T network 
(

Figure 4.6

).

3.

Use a shielded UTP Category 5 cable with RJ-45 
connectors.

Figure 4.6

Network Connection

4.

Power can be supplied one of two ways: 24 VAC power 
connection (factory configured), or via the Ethernet cable 
compliant with the Power-over-Ethernet (IEEE 802.3af) 
standard.

!

CAUTION! 

Never supply power via the Ethernet connection 

(PoE) when power is supplied via the power connector.

!

WARNING! 

If connecting to a PoE LAN switch remove the 

separate AC power connections from the camera.

Summary of Contents for KBE-335V28-20

Page 1: ...KBE and KBN Series Prepackaged Cameras en Instruction Manual ...

Page 2: ......

Page 3: ...escription 15 3 1 Model Summary 15 4 Installation 16 4 1 Operating Voltage 16 4 2 Preparing the Unit 16 4 3 Preparing the Mount 16 4 4 Housing 16 4 5 Line Power and Video Signal Connection 16 4 6 Connections for U Suffix F Suffix and N Suffix 17 4 6 1 U Twisted Pair Suffix Connections 17 4 6 2 Wiring Do s 18 4 6 3 Wiring Don ts 18 4 6 4 F Fiber Optic Suffix Connections 19 4 6 5 N Network Suffix Co...

Page 4: ...iv en Table of Contents KBE and KBN Series F01U078718 2 0 2008 01 Instruction Manual Bosch Security Systems Inc ...

Page 5: ...g and ensure reliable operation Do not block or cover these openings Do not place the unit in an enclosure unless proper ventilation is provided or the manufacturer s instructions have been adhered to 4 Water Do not use this unit near water for example near a bathtub washbowl sink laundry basket in a damp or wet basement near a swimming pool in an outdoor installation or in any area classified as ...

Page 6: ...ns of IEC Publication 227 or IEC Publication 245 10 Power disconnect Units with or without ON OFF switches have power supplied to the unit whenever the power cord is inserted into the power source however the unit is operational only when the ON OFF switch is in the ON position The power cord is the main power disconnect device for switching off the voltage for all units 11 Power sources Operate t...

Page 7: ...allen into the unit unit has been dropped or the unit cabinet is damaged unit exhibits a distinct change in performance unit does not operate normally when the user correctly follows the operating instructions 14 Replacement parts Be sure the service technician uses replacement parts specified by the manufacturer or that have the same characteristics as the original parts Unauthorized substitution...

Page 8: ...ituation If not avoided this could result in serious bodily injury or death CAUTION Medium Risk Indicates a potentially hazardous situation If not avoided this may result in minor or moderate injury Alerts the user to important instructions accompanying the unit CAUTION Low risk without safety alert symbol Indicates a potentially hazardous situation If not avoided this may result in property damag...

Page 9: ... of the building If it is needed to open the housing for servicing and or other activities use this all pole switch as the main disconnect device for switching off the voltage to the unit Camera grounding For mounting the camera in potentially damp environments ensure to ground the system using the ground connection of the power supply connector see section Connecting external power supply Camera ...

Page 10: ...s location of discharge unit connection to grounding electrodes and requirements for the grounding electrode Your Bosch product was developed and manufactured with high quality material and components that can be recycled and reused This symbol means that electronic and electrical appliances which have reached the end of their working life must be collected and disposed of separately from househol...

Page 11: ...rd pin for earth grounding This safety feature allows the plug to fit into a grounded power outlet only If unable to insert the plug into the outlet contact a locally certified electrician to replace the obsolete outlet Do not defeat the safety purpose of the grounding plug Moving Disconnect the power before moving the unit Move the unit with care Excessive force or shock may damage the unit and t...

Page 12: ... like telephone network voltage avoid connecting the SELV circuit to the Telephone Network Voltage TNV circuits Video loss Video loss is inherent to digital video recording therefore Bosch Security Systems cannot be held liable for any damage that results from missing video information To minimize the risk of lost digital information Bosch Security Systems recommends multiple redundant recording s...

Page 13: ...es and radiates radio frequency energy and if not installed and used in accordance with the instruction manual may cause harmful interference to radio communications Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his expense Intentional or unintentional modifications not expressly appr...

Page 14: ...t émet de l energie de fréquence radio et peut en cas d installation ou d utilisation non conforme aux instructions générer des interférences nuisibles aux communications radio L utilisation de ce produit dans une zone résidentielle peut provoquer des interférences nuisibles Le cas échéant l utilisateur devra remédier à ces interférences à ses propres frais Au besoin l utilisateur consultera son r...

Page 15: ... THIS PRODUCT Disclaimer Underwriter Laboratories Inc UL has not tested the performance or reliability of the security or signaling aspects of this product UL has only tested fire shock and or casualty hazards as outlined in UP s Standard s for Safety for Information Technology Equipment UL 60950 1 UL Certification does not cover the performance or reliability of the security or signaling aspects ...

Page 16: ...NOTICE This user guide has been compiled with great care and the information it contains has been thoroughly verified The text was complete and correct at the time of printing The ongoing development of the products may mean that the content of the user guide can change without notice Bosch Security Systems accepts no liability for damage resulting directly or indirectly from faults incompleteness...

Page 17: ...ephone 888 289 0096 Fax 585 223 9180 Email security sales us bosch com Technical Support Telephone 800 326 1450 Fax 585 223 3508 or 717 735 6560 Email technical support us bosch com Repair Center Telephone 585 421 4220 Fax 585 223 9180 or 717 735 6561 Email security repair us bosch com Canada Telephone 514 738 2434 Fax 514 738 8480 Europe Middle East Asia Pacific Region Telephone 44 0 1495 274558 ...

Page 18: ...14 en Safety KBE and KBN Series F01U078718 2 0 2008 01 Instruction Manual Bosch Security Systems Inc ...

Page 19: ...g the unit for service Save it for possible future use 2 1 Parts List Refer to Section 7 Model Numbers and System Specifications page 24 for a detailed list of the Camera Lens Housing and Feed through Mount model numbers included with the various package model numbers 3 Description The KBE and KBN Series are complete camera packages that include a camera and lens pre wired into a housing A feed th...

Page 20: ... the mount using the two 2 1 4 20 screws and washers provided in the hardware kit For additional information see the LTC 9215 00 Mount Installation Manual and UHO HBGS 10 Series Housing Installation Manual 4 5 Line Power and Video Signal Connection The external video coax cable is equipped with a female BNC connector for transmission of video Route and connect video cable to the BNC connector The ...

Page 21: ...l 2 Pass the supplied orange string through the mounting foot of the camera housing and the furnished mount See Figure 4 2 on page 19 A fitting may be used in the mounting foot if desired 3 Attach the end of the string to the unshielded twisted pair UTP video cable and pull it through the mount and the unused hole in the mounting foot of the camera housing as shown in Figure 4 3 on page 20 4 Conne...

Page 22: ...signal is sent as a twisted pair not a split pair 4 6 3 Wiring Don ts 1 DO NOT USE SHIELDED TWISTED PAIR WIRE as this will severely degrade the distance performance Short runs may be used with some signal degradation Multi pair wire with an overall shield is OK 2 DO NOT USE UNTWISTED WIRE as this will reduce the inherent immunity to interference 3 DO NOT allow your installation to have bridge taps...

Page 23: ...dard construction 1 Make all power connections in accordance with the KBE and KBN Series Instruction Manual 2 Pass the supplied orange string through the mounting foot of the camera housing and the furnished mount Note that a fitting is not used in the mounting foot when a terminated fiber optic cable is used Figure 4 2 Pass the String through the Mount 3 Attach the end of the string to the fiber ...

Page 24: ...he fiber optic video connector on the fiber optic transmitter Figure 4 4 Connect the Fiber Optic Cable to the Transmitter Reference Description 1 Orange string 2 ST RJ 45 connector 3 Fiber optic video cable UTP CAT5 cable CAUTION Make sure that the bend radius of the fiber optic cable is in accordance with the cable manufacturer s specifications when dressing the fiber optic cable ...

Page 25: ...e mounting foot of the camera housing with RTV or an equivalent seal If a fitting was used in the mounting foot along with an unterminated fiber optic cable apply the seal around the optical cable before tightening the fitting to prevent slippage A split rubber sleeve not supplied may be used for this purpose Figure 4 5 Seal the Hole in the Housing Foot 7 Attach the housing to the mount in accorda...

Page 26: ...ual 2 Connect the camera to a 10 100 Base T network Figure 4 6 3 Use a shielded UTP Category 5 cable with RJ 45 connectors Figure 4 6 Network Connection 4 Power can be supplied one of two ways 24 VAC power connection factory configured or via the Ethernet cable compliant with the Power over Ethernet IEEE 802 3af standard CAUTION Never supply power via the Ethernet connection PoE when power is supp...

Page 27: ...7 Connect the Cat5 Cat6 cable to the network connector on the back of the camera See Figure 4 4 8 If an unterminated Cat5 Cat6 cable is being used a fitting may be used in the mounting foot of the camera housing The network cable should be terminated with an RJ 45 connector in accordance with the connector manufacturer s recommendations 9 Seal the hole in the mounting foot of the camera housing wi...

Page 28: ...stems Inc 5 Camera Lens Adjustment The camera and lens come factory configured and ready for operation If custom setup is required see the camera Installation Instructions included in the Instruction Booklet Packet Figure 5 1 Removing the Bracket 6 Sunshield A sunshield is provided with the outdoor packages ...

Page 29: ...80 00 LTC 9215 00S 570 2 8 10 mm Vari focal Indoor Monochrome EIA 24 VAC 60 Hz KBE 355V28 20 LTC 0355 20 LTC 3364 50 UHO HBGS 10 LTC 9215 00 570 2 8 10 mm Vari focal Outdoor Monochrome EIA 24 VAC 60 Hz KBN 355V55 20 LTC 0355 20 LTC 3374 50 LTC 9480 00 LTC 9215 00S 570 5 50 mm Vari focal Indoor Monochrome EIA 24 VAC 60 Hz KBE 355V55 20 LTC 0355 20 LTC 3374 50 UHO HBGS 10 LTC 9215 00 570 5 50 mm Var...

Page 30: ...BE 510V75 20F LTC 0510 20 LTC 3274 41 UHO HBGS 10 LTC 9215 00 570 7 5 75mm Vari focal Outdoor Monochrome EIA 24 VAC 60 Hz with Fiber KBE 510V75 20U LTC 0510 20 LTC 3274 41 UHO HBGS 10 LTC 9215 00 570 7 5 75mm Vari focal Outdoor Monochrome EIA 24 VAC 60 Hz with UTP KBE 510V41 20 LTC 0510 20 LTC 3764 20 UHO HBGS 10 LTC 9215 00 570 4 0 12mm Vari focal Outdoor Monochrome EIA 24 VAC 60 Hz KBE 510V41 20...

Page 31: ... HIGH SENSITIVITY KBN 485V28 20 LTC 0485 21 LTC 3364 50 LTC 9480 00 LTC 9215 00S 540 2 8 10 mm Vari focal Indoor Color NTSC 24 VAC 60 Hz KBE 485V28 20 LTC 0485 21 LTC 3364 50 UHO HBGS 10 LTC 9215 00 540 2 8 10 mm Vari focal Outdoor Color NTSC 24 VAC 60 Hz KBE 485V28 20F LTC 0485 21 LTC 3364 50 UHO HBGS 10 LTC 9215 00 540 2 8 10 mm Vari focal Outdoor Color NTSC 24 VAC 60 Hz with Fiber KBE 485V28 20...

Page 32: ...olor NTSC 24 VAC 60 Hz with UTP DAY NIGHT 1 3 in HIGH RESOLUTION KBN 495V28 20 LTC 0495 21 LTC 3664 40 LTC 9480 00 LTC 9215 00S 540 2 8 11 mm Vari focal IR Corrected Indoor Day Night NTSC 24 VAC 60 Hz KBE 495V28 20 LTC 0495 21 LTC 3664 40 UHO HBGS 10 LTC 9215 00 540 2 8 11 mm Vari focal IR Corrected Outdoor Day Night NTSC 24 VAC 60 Hz KBE 495V28 20F LTC 0495 21 LTC 3664 40 UHO HBGS 10 LTC 9215 00 ...

Page 33: ...focal IR Corrected Outdoor Day Night NTSC 24 VAC 60 Hz KBE 620V41 20F LTC 0620 21 LTC 3764 20 UHO HBGS 10 LTC 9215 00 540 4 12 mm Vari focal IR Corrected Outdoor Day Night NTSC 24 VAC 60 Hz with Fiber KBE 620V41 20U LTC 0620 21 LTC 3764 20 UHO HBGS 10 LTC 9215 00 540 4 12 mm Vari focal IR Corrected Outdoor Day Night NTSC 24 VAC 60 Hz with UTP IP COLOR 1 3 in HIGH RESOLUTION KBE 455V28 20N NWC 0455...

Page 34: ...30 en Sunshield KBE and KBN Series F01U078718 2 0 2008 01 Instruction Manual Bosch Security Systems Inc ...

Page 35: ......

Page 36: ...rity Systems Inc 850 Greenfield Road Lancaster PA 17601 USA Telephone 1 888 289 0096 Fax 1 717 735 6565 www bosch securitysystems com 2007 Bosch Security Systems Inc F01U078718 2 0 2008 01 Data subject to change ...

Reviews: