324 | LSN Peripherals | LSN Seismic
•
Acoustic insulation between inlet channel and night
safe
•
Coating the opening cover and the inside of the safe
with sound-absorbing material
•
Using plastic cash boxes
Parts Included
Type
Qty.
Component
GM 570 LSN
1
Seismic detector
Technical Specifications
LSN operating voltage
Max. 33 V_
LSN current consumption
2.43 mA
Measurement output, terminal 9
Analog integration signal
•
Standby level
Approx. 0.7 V
•
Integration start
2.5 V
•
Max. interference level
3.2 V
•
Alarm threshold (no load)
4.0 V
Sensitivity reduction input, terminal 10
•
For reduction
LOW ≤ 1.5 V/HIGH ≥ 3.5 V
•
Reduction
up to 1/8 of the current setting
(SW programmable, depending on
control panel)
Sensitivity adjustable in
6 fixed 1 freely programma-
ble object (SW programmable, de-
pending on control panel)
Effective range (concrete and steel) R=4 m (with default setting)
Detection zone (concrete and steel) 50 m
2
Operating temperature
-20 °C to +70 °C
Humidity: DIN class F
< 95%
Housing protection category
(EN60529, EN50102)
IP 43
VdS environmental class
III
EMC strength 0.01 to 2 GHz
(IEC801-3)
30 V/m
Housing
•
Material
Metal
•
Color
Light gray
Weight
Approx. 0.4 kg
Dimensions (H x W x D)
40 x 90 x 90 mm
GMXBO floor socket (optional)
Dimensions (H x W x D)
•
GMXB0 floor socket
150 x 150 x 50 mm
•
Floor socket with flange
220 x 150 x 50 mm
Maximum load
1000 kg
Protection category
IP 50
Ordering Information
GM 570 LSN Seismic Detector
For monitoring vault doors, modular vaults and
vault walls
4998085573
Bosch Security Systems B.V.
www.boschsecurity.com
6