318 | LSN Peripherals | LSN Motion PIR/Microwave
Plan view
Long-range version with IRS 272 (optional)
At installation heights above 3 m, the detector should point
downward at an angle of 2°.
Side view/top view
The detector requires a stable reference for the entire
detection zone. The detection zone consists of two
subzones (separated by the central level). The subzones
cannot be referenced to different surfaces that may consist
of differing materials. The middle level of a detection zone
is in the detector's longitudinal axis, which is perpendicular
to the installation surface (housing floor).
Not permissible:
Permissible:
1
Material A
2
Material B
3
Outside wall
4
Inside wall
Parts Included
Type
Qty.
Component
IR 270 T LSNi
1
Infrared motion detector
Technical Specifications
IR 270 T LSNi
LSN operating voltage
Max. 33 V DC
Current consumption
•
Maximum current
2.2 mA
Range
•
Wide-angle version
18 m
•
Long-range version
(with IRS 272)
25 m
Installation height
•
Wide-angle version
1.8 m to 2.5 m
•
Long-range version
(with IRS 272)
2.0 m to 4 m
Movement speeds
•
Wide-angle version
0.1 to 4.0 m/s
•
Long-range mirror
0.1 to 4.0 m/s
Environmental conditions
•
Operating temperature
20 °C to +55 °C
•
Storage temperature
-20 °C to +60 °C
•
VdS tested environmental
class II
-10 °C to +55 °C
•
Humidity EN60721
< 95% relative, no dew point
•
EMC strength up to 2 GHz
30 V/m
•
VdS environmental class
II
Housing
•
Dimensions (H x W x D)
135.5 x 55 x 45 mm
•
Housing protection category IP41/IK02
•
Weight
0.150 kg
Bosch Security Systems B.V.
www.boschsecurity.com
6