www.boschsecurity.com
©
2014 Bosch Security Systems, Inc.
F01U261809-04
1
Professional Series
PIR Detectors
with Anti-mask
Installation Instructions
ISC-PPR1-WA16G
ISC-PPR1-WA16H
< 93%
The small animal immunity feature
was not investigated by UL.
IP41/IK04 (EN60529, EN62262)
EN 50131-1 Grade 3
EN 50130-5 Environmental Class II
EN 50131-2-2 Grade 3
SELV
Connect all wiring to a safety extra-low voltage (SELV) circuit only.
Sluit alle bedrading uitsluitend aan op een circuit met een extra lage
veiligheidsspanning.
Prenez soin de connecter tous les câbles à un circuit à très basse tension de sécurité
limité en puissance (TBTS).
This product is intended for use in the following countries within the European Union and in other
countries outside of the European Union:
ISC-PPR1-WA16G (10.525 GHz):
Austria, Belgium, Denmark, Finland, Greece, Italy,
Luxembourg, Netherlands, Norway, Portugal, Spain, Sweden, United States (US), Canada
ISC-PPR1-WA16H (10.588 GHz):
France, United Kingdom
UL, C-UL
Use only a Listed Class 2 Power Limited power source.
Standby Power: For UL and C-UL Listed product installation, the Listed control unit or a
Listed burglary power supply must provide four hours of stand by power.
For C-UL applications, install the unit in accordance with Part 1 of the Canadian Electrical
Code.
NOTE:
Model ISC-PPR1-WA16H is not UL, C-UL listed.
IMQ
Certificato IMQ sistemi di sicurezza 2° livello di prestazione secondo CEI79-2:1998 +
Ab:2000 modello (W18G)
NF A2P
(ISC-PPR1-WA16GH seulement)
Certificat NFA2P Grade 3
ISC-PPR1-WA16G 2630000480
ISC-PPR1-WA16H 2630000480
3 boucliers NF324 - H58 - 110P2
www.afnor.org
www.cnpp.com
INCERT
B-509-0051/d
FCC/IC
This device complies with Part 15 of the FCC Rules and with RSS-210 of Industry and
Science Canada. Operation is subject to the following two conditions: (1) this device may
not cause harmful interferences, and (2) this device must accept any interference received,
including interference that may cause undesirable operation.
-
29°C - +55°C (-20°F - +130°F)
EN 50130-5 Class II: -10°C - +55°C
(+14°F - +131°F)
For UL, C-UL Listed installations, the temperature range is
0°C - +49°C (+32°F - +120°F), humidity 93%
Certificata IMQ: 0°C - +49°C
VdS -10°C- 55°C
Pour les installations certiifées NFA2P, températures de
fonctionnment -10°C, +55°C
Logica:
AND
Segnale microonda:
pulsato
Potenza microonda:
EIRP </= 20 mW
<4.5 kg (10 lb)