Model
Volume setting of beam power control
ISC-FPB1-
W60QS
volume 20
30
40
50
55
60
range
<20 m
(65 ft)
20-30 m
(65-98 ft)
30-40 m
(98-131
ft)
40-50 m
(131-164
ft)
50-55 m
(164-180
ft)
55-60 m
(180-196
ft)
ISC-FPB1-
W120QS
volume 40
60
80
100
110
120
range
<40 m
(131 ft)
40-60 m
(131-196
ft)
60-80 m
(196-262
ft)
80-100 m
(262-328
ft)
100-110 m
(328-360
ft)
110-120 m
(360-393
ft)
ISC-FPB1-
W200QS
volume 60
100
130
160
180
200
range
<60 m
(131 ft)
60-100 m
(131-328
ft)
100-130 m
(328-426
ft)
130-160 m
(426-524
ft)
160-180 m
(524-590
ft)
180-200 m
(590-656
ft)
Upper/Lower Beam Switch
ON - the upper/lower beam turns on. OFF - the upper/lower beam turns off.
Figure 6.3: Beam switch
Callout
ー
Description
Callout
ー
Description
1
ー
Transmitter
3
ー
Lower beam switch 2
2
ー
Upper beam switch 1
4
ー
Beam power control
Photobeam 5000
Setup | en
19
Bosch Security Systems, Inc.
Installation and Operation Guide
2016.02 | 03 | F.01U.305.910