Setup
Turn the Bypass switch on to activate the bypass feature.
1
3
2
Figure 6.1: Receiver Bypass switch
Callout
ー
Description
1
ー
Receiver
2
ー
Bypass switch (switch 1)
3
ー
Sensitivity control
Interruption time
Turn the sensitivity control on the receiver clockwise to reduce sensitivity and
counterclockwise to increase sensitivity.
1
2
3
4
5
Figure 6.2: Interruption time settings
Callout
ー
Description
Callout
ー
Description
1
ー
40 ms running
4
ー
300 ms slow walking
2
ー
75 ms jogging
5
ー
400 – 500 ms slow walking
3
ー
150 – 200 ms walking
Beam power control
Turn the Beam Power Control on the transmitter clockwise to increase beam power. Turn
counter-clockwise to decrease beam power. Refer to table below. For UL applications, the
interruption time cannot exceed 75 ms.
6
18
en | Setup
Photobeam 5000
2016.02 | 03 | F.01U.305.910
Installation and Operation Guide
Bosch Security Systems, Inc.