6 720 680 226
38
Maintenance and service
Fig. 64 Adjusting P2 CO
2
level
6.6
Program values
This section describes details on programming the
appliance. For most applications the factory default
values will provide robust and stable operation. Only
adjust the factory settings if the installation requires
changes as indicated in the appropriate section of this
manual.
Refer to 6.7 Control board diagnostics (page 35)
regarding how to access these P-modes.
6720608158-38.1AL
Caution:
Misadjusted
program
values can lead to appliance
malfunction, errors, and service
calls.
Program
Description
Factory Default
MIN
MAX
Comment
P1
Maximum Power
NG: 51,
LP: 51
21
NG: 53,
LP: 53
see chapter 3.13, page 28
note: reducing P1 values below
maximum will reduce maximum
power of the appliance.
P2
Minimum Power
12
12
20
see chapter 3.3.6, page 16
P3
Remote
Controls installed
_0
_0
6
see chapter 5.5, page 32
P4
Access to
Diagnostic Mode
E
0d
10f
see chapter 6.7, page 39
P5
Cascade Mode
NO
NO
CC
contact Bosch for details
P6
Temperature Unit
°F
°F
°C
P7
Appliance Type
Cd
Cd
NO
Condensing / Non-condensing
note: incorrect setting will cause
errors.
P8
Back light
dE
dE
ON
dE turns back light off after 60
seconds from last button pushed,
ON
turns
backlight
on
permanently
P9
Fan Purge
runs secondary fan and primary
fan when P9 is selected by
depressing the “P” - button
Table 18 Program values, factory default settings and ranges.
* Incorrect setting causes errors.