EN
| 11
Bosch Security Systems | 26 March 2004
e
.
Pull any excess wire out of the housing
and tighten the fitting to 8.5.N.m to
9.0 N.m (75in.lb to 80in.lb). This torque
rating is approximately 1 to 1-1/2 turns
past the point where the fitting starts to
grip the wire.
Be sure to securely tighten all fittings to
ensure a liquid-tight seal. Failure to do
this could allow water to enter the
housing and damage electronic parts,
camera, and lens.
f.
Connect the supply power wires to the
terminal block (see WIRING
DIAGRAM in Table 1). Strip no less
than 6mm (0.25in) and no more than
8mm (0.31in) of insulation away from
the wire. Be sure not to nick the wires.
g.
Cut the power cord on 115VAC and
230VAC camera models; leave enough
cable to allow connection to the
terminal block. Strip no less than 6mm
(0.25in) and no more than 8mm (0.31in)
of insulation away from the wire. Be
sure not to nick the wires. Connect these
wires to the connectors provided on the
terminal block (see WIRING
DIAGRAM in Table 1).
h.
On heater and heater/blower units,
make sure the heater and fan wires stay
connected to the terminal block.
Table 1 - Wiring Diagram
Pin Color
Connection
1
Blue
Power Connection
1,2
2
Brown Power Connection
1
3
---
N/C (No Connection)
4
Green
G (Safety Ground)
Notes:
1
24VAC, 115VAC, or 230VAC, depending on the housing model.
2
Pin-2 is internally fused and should be connected to the hot side
of the mains for 115VAC and 230VAC models.
4.7
Video Coax Connection
See SECTION 5 for HSG9483/22, HSG9483/52, and
HSG9483/53 Models.
WARNING: For wiring video coax
connections, use only the cables specified
under INSTALLATION, Cable
Requirements.
1.
Install a 3/8in. NPT fitting into the next
available hole in the rear cap.
2.
Route the video coax cable through one of the
fittings installed in Step 1, or one of the feed-
through fittings in the base.
3.
Attach the BNC connector to the coax and
connect it to the camera. Pull any excess wire
out of the housing and tighten the fitting to
8.5 N.m to 9.0 N.m (75in.lb to 80in.lb). This
torque rating is approximately 1 to 1-1/2 turns
past the point where the fitting starts to grip the
wire.
Be sure to securely tighten all fittings to
ensure a liquid-tight seal. Failure to do this
could allow water to enter the housing and
damage electronic parts, camera, and lens.
If a sealant is used, be sure it is a neutral cure
type. Sealants that release acetic acid may
harm camera electronics.
Use of
drip loops
is recommended on the
wiring outside of the rear end cap.
HSG9483 Series
|
Instruction Manual
|
Installation