background image

EN

| 8

Bosch Security Systems | 26 March 2004

HSG9483 Series 

Instruction Manual

Installation

4

INSTALLATION

CAUTION: These units must be properly

and securely mounted to a supporting
structure capable of sustaining the unit
weight. Use care when selecting mounts or
pan/tilts (not supplied) for installation; the
mounting surface and unit's weight should be
carefully considered.

4.1

Tools Required

Small flat blade screwdriver

Phillips screwdriver (#1)

Adjustable wrench

Wire cutter/stripper/crimper tool

4.2

Cable Requirements

Video Transmission (Coaxial)

Cable Type:

RG-59/U for runs < 300m (1000ft)
RG-11/U for runs < 600m (2000ft)

Cable Size:

Outside diameter between 
4.6mm (0.181in)-7.9mm (0.312in)

Cable Shape:

Round

Shield:

> 93% Braided copper shield

Center Conductor:

Stranded copper center

DC Resistance:

< 15

/1000 (RG-59/U)

< 6

/1000 (RG-11/U)

Cable Impedence:

75

Agency Rating:

UL

Environmental:

Outdoor rated

Temperature Rating: > 80°C

Sources:

Belden 9259

Input Power Cord - North American

Cable Type:

SJTOW rated

Cable Size:

Outside diameter between
4.3mm (0.170in)-11.9mm (0.470in)

Cable Shape:

Round

Conductors:

3-conductor version and 
2-conductor version

Agency Rating:

UL/C.S.A., UL VW-1

Environmental:

Outdoor rated

Temperature Rating: 105°C

Voltage Rating: 

300 V

Sources:

Belden 19509, 3-conductor
Northwire FSJT183-81K, 3-conductor

Input Power Cord - European

Cable Type:

H05RN-F 3 G 0.75 and
H05RN-F 3 G 1.00

Cable Size:

Outside diameter between
4.3mm (0.170in)-11.9mm (0.470in)

Cable Shape:

Round

Conductors:

3-conductor version and
2-conductor version

Agency Rating:

VDE

Environmental:

Outdoor rated

Sources:

Olflex rubber cable 1600 252
Olflex rubber cable 1600 253

Lens Control Cable

Cable Type:

Jacketed multiconductor cable

Cable Size:

Outside diameter between
4.3mm (0.170in)-11.9mm (0.470in)

Cable Shape:

Round

Shield:

Overall shielding

Conductors:

Stranded 20 to 16AWG wire

No. of Conductors:

4 and 8

Conductor Insulation: Color coded

Sources:

Belden 9552, 4-conductor
Belden 9554, 8-conductor

4.3

Housing Mounting

1.

Use the two 1/4-20 x 0.50in. screws and 
1/4in. spring washers provided in the hardware
kit to mount the housing to a mount or a
pan/tilt. The spring washers must be used for
the screws to thread properly.

2.

The outermost set of 1/4-20 threaded holes are
for mounting to feed-through mounts and the
innermost 1/4-20 holes are for mounting to all
other mounts and pan/tilts.

4.4

Opening the Cover

1.

Open the cover by unlatching the two clasps
on the side of the housing (see FIGURE 1).

Figure 1:  Unlatching the Cover

NOTE: If the optional tamper-resistant screws have

been installed, use the supplied wrench to
remove the screws before opening the latches.

Summary of Contents for HSG9483 Series

Page 1: ...Instruction Manual EN Environmental Enclosures HSG9483 Series ...

Page 2: ...cal shock or other hazards 9 Safety Check Upon completion of servicing or repairs to the unit ask the service technician to perform safety checks to ensure proper operating condition 10 Power Sources Operate the unit only from the type of power source indicated on the label If unsure of the type of power supply to use contact your dealer or local power company For units intended to operate from ba...

Page 3: ... models only refer to the National Electrical Code Article 820 regarding installation of CATV systems For Rack mount Product 1 Ventilation This unit should not be placed in a built in installation or rack unless proper ventilation is provided or the manufacturer s instructions have been adhered to The equipment must not exceed its maximum operating temperature requirements 2 Mechanical Loading Mou...

Page 4: ...er sollte sich ausführlich über Anweisungen für die Bedienung und Instandhaltung Wartung in den begleitenden Unterlagen informieren Precauciones de Seguridad Atención la instalación la debe realizar únicamente personal cualificado de conformidad con el National Electric Code o las normas aplicables en su país Desconexión de la alimentación Las unidades con o sin interruptores de encendido apagado ...

Page 5: ...duzido na fonte de alimentação contudo a unidade apenas está operacional quando o interruptor ON OFF está na posição ON O fio de alimentação destina se a desligar a corrente em todas as unidades CUIDADO PARA REDUZIR O RISCO DE CHOQUE ELÉCTRICO NÃO RETIRE A TAMPA OU A PARTE POSTERIOR NO INTERIOR NÃO EXISTEM PEÇAS QUE POSSAM SER REPARADAS PELO UTILIZADOR REMETA A ASSISTÊNCIA PARA OS TÉCNICOS QUALIFI...

Page 6: ...over 8 4 5 Camera Lens Installation 9 4 6 Camera Lens Wiring 9 4 7 Video Coax Connection 11 4 8 Lens Wiring 12 4 9 Camera Lens Adjustment 12 4 10 Final Assembly 12 4 11 Sunshield 12 4 12 Fuse Replacement 12 5 HSG9483 22 HSG9483 52 HSG9483 53 MODELS 13 5 1 Camera Lens Wiring 13 5 2 Video Coax Connections 13 6 OPERATION 14 7 MAINTENANCE 14 8 SERVICE PARTS 14 9 EXPLODED VIEW 15 HSG9483 Series Instruc...

Page 7: ...L mm 3 2 x 3 5 x 12 5in Outdoor Units HSG9483 20 Htr SS 24VAC 30 W 24VAC 81 W x 89 H x 262 L mm 3 2 x 3 5 x 10 3in HSG9483 21 Htr Blr SS 24VAC 35 W 24VAC 81 W x 89 H x 262 L mm 3 2 x 3 5 x 10 3in HSG9483 22 2 Htr Blr SS 24VAC 35 W 24VAC 81 W x 89 H x 262 L mm 3 2 x 3 5 x 10 3in HSG9483 50 Htr SS 230VAC 30 W 230VAC 81 W x 89 H x 262 L mm 3 2 x 3 5 x 10 3in HSG9483 51 Htr Blr SS 230VAC 35 W 230VAC 8...

Page 8: ...C Voltage Rating 300 V Sources Belden 19509 3 conductor Northwire FSJT183 81K 3 conductor Input Power Cord European Cable Type H05RN F 3 G 0 75 and H05RN F 3 G 1 00 Cable Size Outside diameter between 4 3mm 0 170in 11 9mm 0 470in Cable Shape Round Conductors 3 conductor version and 2 conductor version Agency Rating VDE Environmental Outdoor rated Sources Olflex rubber cable 1600 252 Olflex rubber ...

Page 9: ... the lens to the camera tray see FIGURE 5 Figure 5 Attaching Camera with Zoom Lens 4 6 Camera Lens Wiring See SECTION 5 for HSG9483 22 52 53 Models WARNING To wire cameras and lenses use only the cables specified under INSTALLATION Cable Requirements 1 Fittings a The two 3 8in NPT fittings accept a round cable with diameter from 4 0mm 0 16in to 7 0mm 0 28in The larger 1 2in NPT fitting will accept...

Page 10: ...0 27 90 1 18 42 140 1 5 16 67 220 2 5 14 108 355 4 12 172 565 NOTE Wire sizes larger than 2 5mm2 14AWG require a splice to accomodate the terminal block a Install one of the large 1 2in NPT fittings into one of the holes in the rear cap If using the feed through option ignore this step b Route the power cable through the fitting in the rear cap or one of the feed through fittings in the foot c The...

Page 11: ...nection1 2 2 Brown Power Connection1 3 N C No Connection 4 Green G Safety Ground Notes 1 24VAC 115VAC or 230VAC depending on the housing model 2 Pin 2 is internally fused and should be connected to the hot side of the mains for 115VAC and 230VAC models 4 7 Video Coax Connection See SECTION 5 for HSG9483 22 HSG9483 52 and HSG9483 53 Models WARNING For wiring video coax connections use only the cabl...

Page 12: ...ecommended on the wiring outside of the rear end cap 4 9 Camera Lens Adjustment 1 Verify operation of the camera and lens before final assembly Adjust the camera focus and iris as necessary See camera instructions 4 10 Final Assembly 1 Use the hole plugs provided to plug any unused holes in the rear cap 2 Replace the camera and bracket back into the housing Slide the camera lens tray into the slot...

Page 13: ...lice to a smaller size wire at the terminal block end 4 Connect the power input cable to the screw terminals on the provided mating connector see FIGURE 9 and Wiring Diagram for pin connections Table 2 Wiring Diagram 4 Pin Pin Function Harness Wire Color 1 AC Neutral Blue 2 AC Hot Brown 3 No Connection Do not use 4 Ground Green Yellow WARNING Use only 24VAC power for HSG9483 22 Models These models...

Page 14: ...o special maintenance is required other than occasional cleaning of the window 8 SERVICE PARTS Description Part No Spacer 4mm ABS 77018 00 Spacer 9mm ABS 77019 00 Screw Tamper resistant 77029 00 Wrench Tamper resistant 87017 00 Fittings 3 8in NPT 87018 00 Fittings 1 2in NPT 87019 00 Hole Plug Sunshield 85428 00 Hole Plug 3 8in NPT 77072 00 Hole Plug 1 2in NPT 77071 00 Hole Plug Bottom feed 87048 0...

Page 15: ...0 115VAC Fan Kit for HSG9483 61 6 35727 00 24V 220VAC Fan Kit for HSG9483 20 50 52 Without BLR 7 35721 00 24VAC Heater Kit HSG9483 20 21 22 Ref Part Description 8 35722 00 115VAC Heater HSG9483 61 9 35723 00 220VAC Heater Kit HSG9483 50 51 52 53 10 36002 00 Rearcap Kit for HSG9483 00 20 21 50 51 61 11 36003 00 Rearcap Kit for HSG9483 22 24VAC 12 36004 00 Rearcap Kit for HSG9483 52 53 230VAC 13 770...

Page 16: ...rity Systems Inc 850 Greenfield Road Lancaster PA 17601 USA Tel 800 326 3270 Fax 1 717 735 6560 www boschsecuritysystems com Bosch Security Systems B V P O Box 80002 5600 JB Eindhoven The Netherlands Tele 31 40 27 80000 Bosch Security Systems Pte Ltd 38C Jalan Pemimpin Singapore 577180 Republic of Singapore Tel 65 6 319 3486 ...