Page 9 from 56
6-720-821-364 SM HP270
– 250 - 200 2016/12 en
Pict.5 – Parameters overview in main and sub menu of HP270-3 / HP200/250-1
Applicable to HP-3 with software version:
HPAF2501
(-10ºC / + 35ºC models) (HP270-3)
HPAF2701
(+5ºC / +35ºC models) (HP270-3)
HPAF2801
(+5ºC / +35ºC models) (HP200/250-1)
Operation Mode
Evaporator
Compressor
Solenoid Pump
E-Heater
Combi Mode
Conditions (Man /
Aut)
ON if compressor is
ON
Note:
If Duct On
starts 2 min before
compressor and if
Duct Off starts 1 min
before compressor in
order to update air
temperature value
ON if -10ºC <
T
air
< +35ºC
and T
dis
< 61ºC
and T
top
< 58ºC
(same for +5ºC
model)
OFF
ON if
compressor is
ON
or
ON
if E-heater ON
when
compressor is
OFF
ON if compressor
cannot work due air
temperature
conditions
(T
air
< -10ºC or T
air
> 35ºC)
or T
dis
> 63ºC or T
top
> 60ºC
Economic Mode
Conditions (Man /
Aut)
ON if -10ºC <
T
air
< +35ºC
and T
top
< 60ºC
OFF
ON if T
air
< -10ºC
Or
T
air
> 35ºC
(same for +5ºC
model)
Electric Heater
Mode Conditions
(Man / Aut)
OFF
OFF
OFF
ON
ON