3. Replace Main Cooktop Orifices
Remove Grates, Burner Caps and Burner Bases.
Remove
burner grates and burner caps. Unscrew 2 T20 screws inside
each base and remove burner bases (See Figure 2). Reinsert
screws in jet holder to hold tubing assembly in place.
Remove Natural Gas Cooktop Orifices
. Insert the socket
driver with 3” minimum extension into the jet holders to re-
move existing orifices. Place the old orifices in the space pro-
vided on page 5 in case future conversion back to natural gas
is necessary.
Assemble LP Cooktop Orifices.
Place in cooktop exactly as
layed out in the cover of this manual (also shown in Figure 3).
If the orifices become separated from the cover, placement
can be determined by matching the number stamped into the
orifice with the placement specifications displayed in Figure 4.
Place the new orifice into the socket then insert each orifice
into its respective threaded hole in the jet holder.
Tighten until
the orifice stops turning. DO NOT OVER TIGHTEN.
Conversion Instructions - Before you begin
2. Convert Pressure Regulator from 5”
W.C. to 10” W.C.
1. Remove Warming Drawer; Pull drawer out until stop is
reached. Push clip on right side up and clip on left side
down. Pull drawer the rest of the way out.
2. Remove cover plate from interior back wall by removing
single screw on left side of panel.
3.
Remove the hexagon cap from the top of the regulator
with an adjustable wrench.
4. Pop out the plastic stem in the cap and turn it over pressing
it firmly in place so that the letters “LP” can now be seen
upright in the stem, rather than “NAT”.
5. Replace the cap and button assembly into the top of the
regulator sealing it firmly. Make certain spring is still in place
(See Fig. 1). DO NOT OVER TORQUE.
6. Install the FOIL CONVERSION STICKER on the back side of
the cover plate so that it appears on the back side of range
next to the regulator.
Figure 2
Remove Grate, Cap and Base
!
1.
CAUTION: Turn off Gas and Electricity
Before Proceeding with the conversion; shut off
the gas supply to the appliance prior to discon-
necting the electrical power.
Shut off the outside propane tank gas valve to the range. Re-
move range power cord from electrical outlet or turn breaker
off at breaker box, and turn all control knobs to the “OFF” posi-
tion.
Grate
Burner Cap
Burner Base
Orifice
Ignitor
BACK OF RANGE
Figure 3
Left Rear Burner -
11,000 BTU/h
101
Right Rear Burner -
5,000 BTU/h
70
Left Front Burner -
7,500 BTU/h
86
Right Front Burner -
15,000 BTU/h
116
LP Cooktop Orifice Placement
FRONT OF RANGE
!
NAT
LP
NAT
Hex
Cap
Pin
Position
for Nat.
Gas
Pin
Pin Position
for Propane
Hex
Cap
LP
Pin
Spring
PRESSURE REGULATOR VIEW
Figure 1
Convert Pressure Regulator
2