background image

Page 12

Attaching flue duct 

Hidden surfaces may have sharp edges. Use caution

when reaching behind or under appliance.

1.  Remove the protective foil from both flue ducts.
2.  Push one flue duct into the other. 

 Notes

 

• To prevent scratches, lay paper over the edges of 

  the lower flue duct to protect the surface.

 

• For ducted operation, turn the upper flue duct so 

  that the ventilation slots point downward.

3.  Remove the protective foil from the extractor hood.
4.  Place flue ducts on the appliance.
5.  Push the inner flue duct upwards and attach it to the 

  angle brackets on the left and right.
6.  Screw the flue duct to the sides of the angle bracket 

  using two screws.

A

B

A Installation pipe 

B Power connection 

C Cable connector listed in UL

7.  Fasten the lower part of the flue duct using two 

 screws. 

8.  Remove the protective paper from the lower flue duct.
9.  Install metal-mesh grease filter. 

Removing the appliance 

1.  Remove the metal-mesh grease filter.
2.  Loosen the flue duct.
3.  Disconnect the appliance from the power supply.
4.  Loosen the exhaust air lines.
5.  Loosen screws for fastening the appliance.
6.  Remove the appliance.

Summary of Contents for HCP30E52UC

Page 1: ...Hood Installation Manual Models HCP36E52UC HCP30E52UC HCP34E52UC ...

Page 2: ...tes that death or serious injuries may occur as a result of non observance of this warning CAUTION This indicates that minor or moderate injuries may occur as a result of non observance of this warning NOTICE This indicates that damage to the appliance or property may occur as a result of non compliance with this advisory Note This alerts you to important information and or tips This Bosch applian...

Page 3: ...ce if it is not working properly or if it has been damaged Contact an authorized servicer Do not repair or replace any part of the appliance unless specifically recommended in this manual Refer all servi cing to a factory authorized service center CAUTION Grease left on filters can melt and move into the vent WARNING Hidden surfaces may have sharp edges Use caution when reaching behind or under ap...

Page 4: ... practices by qualified persons Do not allow anyone to climb stand lean sit or hang on any part of an appliance This can damage the appliance or cause injury WARNING Be sure the entire appliance including the grease filters and light bulbs if applicable has cooled and grease has solidified before attempting to clean any part of the appliance Do not use steam cleaners to clean the appliance Proposi...

Page 5: ...quirement 120 VAC 60 Hz 15 A see rating plate The appliance complies with protection class 1 and must only be operated in conjunction with a protective conduc tor terminal An all pole isolating switch with at least a 3 mm contact gap must be fitted in the installation This must remain accessible after installation Only a qualified electrician who takes the appropriate regulations into account may ...

Page 6: ...d Extractor hood with fan back pressure flap Lamp already installed Metal grease filter Flue duct Drill template 1x angle bracket for the flue duct Installation manual and instructions for use 6x screws 5x45 mm 8x screws 4x8 mm 2x washers 2x hollow wall plugs 8x40 mm 4x hollow wall plugs 10x50 mm Torx adapter 10 20 Appliance Dimensions 24 610 mm or 30 762 mm or 36 914 mm A 1911 16 500 mm 77 8 200 ...

Page 7: ...pes before installation Seal the connection points of the pipes appropriately Round pipes An inner diameter of Ø 8 200 mm is recommended Checking the wall The wall must be level vertical and adequately load bearing The depth of the bore holes must be the same length as the screws The wall plugs must have a secure grip The enclosed screws and wall plugs are suitable for solid brickwork Suitable fas...

Page 8: ... 2 2 10 10 3 x 10 90 elbow round N A 5 2 long 3 x 10 flex N A 20 3 x 10 45 elbow round N A 15 3 x 10 Flat elbow N A 20 6 1 8 10 8 2 3 x 10 Roof jack and shutter N A 6 5 6 10 NOTE These commonly used installation parts can be purchased at a local hardware store Bosch does not manufacture all these parts Round wall cap Round roof cap 3 x 10 to round 90 elbow Duct Piece 3 x 10 Center reverse elbow le...

Page 9: ...r similar material to create an air tight path and to minimize building heat loss and gain and reduce the potential for condensation Place wrap insulation around duct and or fan to in order to minimize possible condensation buildup within the duct building heat loss and gain Preparing the installation 1 Mark a vertical center line on the wall from the ceiling to the lower edge of the extractor hoo...

Page 10: ...tractor hood on the upper screws on the wall 6 Mark holes for the lower holes 7 Remove the extractor hood from the wall 8 Drill the lower holes 9 Hang the extractor hood on the upper screws on the wall 10 Tighten the upper and lower screws by hand Mounting the back pressure flap Using 4 screws 4x8 mm attach the back pressure flap to the extractor hood Connecting the air extractor only for ducted o...

Page 11: ... wiring the appliance interrupt the main electrical circuit at the electrical control cabinet A circuit with 120 VAC 15 or 20 Ampere is required Grounding notes this appliance is equipped with a distributor box with 3 cables Use the green yellow cable for grounding the appliance Connect the green yellow cable to the grounding cable on the house connection to prevent electric shock Do not under any...

Page 12: ...ace flue ducts on the appliance 5 Push the inner flue duct upwards and attach it to the angle brackets on the left and right 6 Screw the flue duct to the sides of the angle bracket using two screws A B A Installation pipe B Power connection C Cable connector listed in UL 7 Fasten the lower part of the flue duct using two screws 8 Remove the protective paper from the lower flue duct 9 Install metal...

Reviews: