Page 11
2. Measure the distance (x) between the bottom edge of
the housing for the recirculation module and the
bottom edge of the back-pressure flap.
A
x
B
C
D
A Recirculation module
B Clamps
C Flue duct
D Exhaust air duct
3. Shorten the exhaust air pipe to the length measured.
4. Remove the recirculation module.
5. Push the exhaust air pipe onto the bottom side of the
recirculation module.
6. Position the recirculation module with exhaust air pipe
over the air extraction duct of the extractor hood.
7. Use 4 screws to fasten the recirculation module to the
angle bracket.
8. Secure connections with clamps.
Connect Electrical Supply
WARNING
RISK OF ELECTRIC SHOCK
Before wiring the appliance, interrupt the main electrical
circuit at the electrical control cabinet. A circuit with 120
VAC, 15 or 20 Ampere is required.
Grounding notes: this appliance is equipped with a
distributor box with 3 cables. Use the green-yellow cable
for grounding the appliance. Connect the green-yellow
cable to the grounding cable on the house connection to
prevent electric shock. Do not under any circumstances
damage or remove the green-yellow cable. Non-adheren-
ce can cause deadly injuries or electric shock.
1. Remove the left cable passage and the cover of the
motor controller. Fasten the connecting piece for the
installation pipe (listed in cULus) to the cable
passage.
A
B
A Cable passage
B Cover of the motor controller
2. Connect 1/2” (12.7 mm) installation pipe to motor
controller.
A
B
C
A Installation pipe
B Power connection
C Cable connector listed in UL