24
Gas regulating (only for approved contractors)
Therm 4000 S – 6 720 815 298 (2017/05)
▶ Press the
key.
The display shows "P1".
The setting of the maximum gas volume is completed.
7.4.3 Setting the minimum gas volume (parameter P2)
▶ Press
until the display shows "P2".
▶ Press the
key.
The display shows "E".
▶ Press
until the display shows "L2".
▶ Press the
key.
▶ Open one hot water tap.
The minimum gas volume can be set at the device.
▶ Press
or
, until the pressure gauge displays the
value given in Tab. 17.
▶ Hold down
for 3 seconds.
The value flashes as confirmation.
▶ Press the
key.
The display shows "L2".
▶ Close the hot water tap.
▶ Press
until the display shows "E".
▶ Press the
key.
The display shows "P2".
▶ Press the
,
and
keys simultaneously and
hold them down for 3 seconds.
The display shows the selected temperature.
▶ Disconnect the pressure gauge from the test ports [A] and
[B].
▶ Tighten the sealing screws for test ports [A] and [B].
The setting of the minimum gas volume is completed.
7.4.4 Adjustment of the burner nozzle pressure
(parameter P0)
▶ Call up Service mode (
Section 7.2).
The display shows "P2".
▶ Press
until the display shows "P0".
▶ Press the
key.
▶ Open one hot water tap.
Wait until the measured value on the pressure gauge has
stabilised.
▶ Press
or
, until the pressure gauge displays the
value given in Tab. 17.
▶ Hold down
for 3 seconds.
The value flashes as confirmation.
▶ Press
to leave the mode.
The display shows P0.
▶ Close the hot water tap.
▶ Remove the pressure gauge from the test port.
▶ Tighten the sealing screw on the test port [B].
The adjustment of the burner nozzle pressure is
completed.
7.4.5 Factory setting (parameter P4)
▶ Call up Service mode (
Section 7.2).
The display shows "P2".
▶ Press
until the display shows "P4".
▶ Press the
key.
The display shows "E".
▶ Press the
key, until the display shows "rP".
▶ Press the
key.
The display shows "P1".
If the value cannot be reached:
▶ Adjust the burner pressure (Section
7.4.4) and repeat the setting
procedure.
Natural
gas H
(G20)
Natural
gas L
(G25)
Butane Propane
Ø injector
1.8
1.3
Gas supply
pressure
(mbar)
20
25
28-30 /
50
30 / 37/
50
Nozzle
pressure
(mbar) - P0
1.2
Table 17 Burner pressure
Adjustment
range of
max. nozzle
pressure
(mbar) - P1
4,1 - 4,5
6,3 - 6,7
4,9 - 5,3 6,2 - 6,6
Adjustment
range of
min. nozzle
pressure
(mbar) - P2
0,5 - 0,7
0,8 - 1,0
0,6 - 0,8 0,8 - 1,0
It is only necessary to adjust the burner
pressure, if the values "L1" and "L2" cannot
be reached:
Natural
gas H
(G20)
Natural
gas L
(G25)
Butane Propane
Table 17 Burner pressure
Summary of Contents for GWH 12 CTDE 31 F5 S7805
Page 29: ...29 Therm 4000 S 6 720 815 298 2017 05 Notes ...
Page 30: ...Bosch Thermotechnik GmbH Junkersstrasse 20 24 D 73249 Wernau www bosch thermotechnology com ...
Page 31: ...Bosch Thermotechnik GmbH Sophienstrasse 30 32 D 35576 Wetzlar www bosch thermotechnology com ...
Page 32: ...29 Therm 4000 S 6 720 815 298 2017 05 Notities ...