Summary of Contents for GVS1000

Page 1: ...Global View Station 1000 GVS1000 en Operations Manual ...

Page 2: ......

Page 3: ...oting 22 5 1 General 22 5 2 Troubleshooting with Diagnostic Mode 23 6 Test Software 24 6 1 PTCR 20 Software Operation 24 6 1 1 Default Parameters 26 6 1 2 Using PTCR 20 to Set Soft Limits and Camera Control 26 6 1 3 Inverting Tilt Controls 28 6 1 4 Other Menus 28 6 2 Auxiliary Control Board 29 6 2 1 Reset Button 30 6 2 2 Address Selection 30 6 2 3 Protocol Selection 30 6 2 4 System Communication 3...

Page 4: ...tput Indicator 32 6 4 5 T7 SLED 2 Power Output Indicator 32 6 5 Camera Control Board 33 6 5 1 Reset Button 34 6 5 2 System Communication 34 6 5 3 Camera Control Power Indicator 34 6 5 4 Address Selection 34 6 5 5 Protocol Selection 34 6 5 6 Termination Jumpers 34 6 6 Auxiliary Controls 35 6 6 1 Aux 1 2x Doubler Function 35 6 6 2 Aux 2 Wiper Function 35 6 6 3 Aux 3 Illuminator Control 35 6 6 4 Aux ...

Page 5: ... presence of important operation and maintenance servicing instructions in the literature accompanying the product CAUTION This grounding symbol indicates the safety ground of the unit WARNING TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK DO NOT EXPOSE THIS APPARATUS TO RAIN OR MOISTURE AND OBJECTS FILLED WITH LIQUIDS SUCH AS VASES SHOULD NOT BE PLACED ON THIS APPARATUS TO COMPLETELY DISCONNECT THI...

Page 6: ...If the provided plug does not fit into your outlet consult an electrician for replacement of the obsolete outlet 10 Protect the power cord from being walked on or pinched particularly at plugs convenience receptacles and the power where they exit from the apparatus 11 Only use attachments accessories specified by the manufacturer 12 Use only with the cart stand tripod bracket or table specified by...

Page 7: ...nal Follow proper safety precautions such as grounding for any outdoor device connected to this unit U S A models only Section 810 of the National Electrical Code ANSI NFPA No 70 provides information regarding proper grounding of the mount and supporting structure grounding of the coax to a discharge unit size of grounding conductors location of discharge unit connection to grounding electrodes an...

Page 8: ...ection must be in accordance with NEC725 and NEC800 CEC Rule 16 224 and CEC Section 60 Permanently connected equipment Incorporate a readily accessible disconnect device in the building installation wiring Pluggable equipment Install the socket outlet near the equipment so it is easily accessible Power resupply If the unit is forced to power down due to exceeding the specified operating temperatur...

Page 9: ...ll not be made Any such modifications could void the user s authority to operate the equipment If necessary the user should consult the dealer or an experienced radio television technician for corrective action The user may find the following booklet prepared by the Federal Communications Commission helpful How to Identify and Resolve Radio TV Interference Problems This booklet is available from t...

Page 10: ...ce n 004 000 00345 4 Copyright This manual is the intellectual property of Bosch Security Systems and is protected by copyright All rights reserved Trademarks All hardware and software product names used in this document are likely to be registered trademarks and must be treated accordingly NOTE This manual has been compiled with great care and the information it contains has been thoroughly verif...

Page 11: ...al Support Telephone 800 326 1450 Fax 585 223 3508 or 717 735 6560 E mail technical support us bosch com Canada Telephone 514 738 2434 Fax 514 738 8480 Europe Middle East Africa Region Repair Center Telephone 31 0 76 5721500 Fax 31 0 76 5721413 E mail RMADesk STService nl bosch com Asia Region Repair Center Telephone 65 63522776 Fax 65 63521776 E mail rmahelpdesk sg bosch com Customer Service Tele...

Page 12: ...es It is also important to ensure the lens is in the appropriate IR or visible mode depending on the type of light on scene If an incorrect lens setting is being used it may not be possible to focus the lens See the description of the Lens IR filter function Aux 5 2 3 Presets Preset commands allow the system to automatically pan tilt zoom and focus to a pre defined position Some preset commands ar...

Page 13: ... 81 83 By programming any of these three presets it will initiate tour programming and instruct the system that the following preset commands are to set a preset tour Depending on the preset selected the system will store the commands to a specific tour Program Preset 81 Start tour 1 programming Program Preset 82 Start tour 2 programming Program Preset 83 Start tour 3 programming Define the tour u...

Page 14: ...ion For example while performing a tour operation consisting of panning clockwise tilting down and zooming in simultaneously an auxiliary command is used while these tour operations are active these same commands will continue until the limits are reached Reaching the above limits would equate to reaching the clockwise pan limit reaching the down tilt limit and reaching maximum zoom setting 2 6 Au...

Page 15: ...l mode When Aux4 is engaged the lens iris can be manually controlled remotely with iris open close commands Upon initialization the iris will close and will require manual operation to open Aux 5 Lens IR Correction On Off Aux5 ON or Call preset 55 IR corrected mode on Aux5 OFF or Call preset 65 IR corrected mode off Default IR corrected mode off The setting of the lens mode is crucial to ensure op...

Page 16: ...seful for long range imaging when insufficient levels of ambient light are on scene Ensure the illuminators are properly aligned for maximum performance Aux 8 SLED LED On Off Aux8 ON or Call preset 58 SLED illuminators on Aux8 OFF or Call preset 68 SLED illuminators off Default SLED illuminators off The SLED illuminators are wider angle short to medium range units using 3D diffuser and Constant Li...

Page 17: ...port The Pelco code translator box has four 4 status LEDs as shown below Figure 3 1 LEDs on the Pelco Code Translator During normal operation the Rx light will flash whenever valid communication is received by the code translator box Communication specific to the motor will cause the Tx light to flash as the unit sends commands to the motor In Pelco D mode the Rsp light flashes when data is being ...

Page 18: ...n Figure 3 2 the Pelco P D code translator and the Biphase translator unit item 1 below The Biphase translator has four status LEDs but only two are operational Figure 3 2 Location of Biphase code Translator inside GVS1000 Power Supply Unit During normal operation the Rx and Tx lights flash when valid communication with the correct address is received by the code translator box Figure 3 3 LEDs on ...

Page 19: ...rence For complete information on the cameras settings please refer to the camera manual The Mode Menu setting is accessed by pressing the center Menu Select key for less than 1 second The Installer Menu setting is accessed by pressing the Menu Select key for at least 1 second Figure 4 1 OSD keypad location on camera Figure 4 2 OSD keypad detail showing back focus lock 1 Left Key 2 Up Key 3 Menu S...

Page 20: ...LC ALC Level 0 Peak Average 0 ALC Speed Medium DVR IP Encoder On Shutter AGC Shutter AES Default Shutter 1 250 Gain Control AGC Maximum AGC 15 SensUp 2x Day Night Day Night Day Switch Level 0 Priority Color IR Contrast Normal Color Burst On Enhance Dynamic Engine XF Dynamic XF DYN Autoblack On Black Level 0 Sharpness 10 DNR Auto Peak White Invert OFF Color White Balance ATW Speed Medium Red Gain 0...

Page 21: ...1 Bosch Security Systems Inc Operations Manual F 01U 173 867 2 0 2010 11 Installer Menu The table below shows the Installer Menu default camera settings for the camera Submenu Function Value Lens Wizard Lens Type Video Alarm I O Alarm I P Low Alarm Action Mono ...

Page 22: ...nt The Pan Tilt motor drifts when trying to control the GVS1000 The Pan Tilt motor drifts when the communication lines are incorrectly terminated The termination for the auxiliary control board is set through jumper JP6 The termination for the camera board is set through jumper JP3 Toggle the termination on the camera control board first to solve the drifting problem If the problem persists the au...

Page 23: ...nto the illuminators to check for the red glow The red glow can be observed by looking at the illuminators from an angle Check that the illuminators are properly aligned See the installation manual for the IR illuminator alignment procedure Check that the lens IR filter is on Aux 5 on and that the camera is in night mode Aux 6 on Both settings are required for IR sensitivity An auxiliary does not ...

Page 24: ...Windows 9x software and Windows XP It is NOT compatible with Windows NT or Windows 2000 When using the PTCR 20 test software the GVS1000 can be operated directly from a bi directional link compatible with RS422 6 1 PTCR 20 Software Operation Install the PTCR 20 Remote Emulator using the supplied CD Connect the GVS1000 to the PC using an RS232 straight cable Unplug the green terminal blocks from th...

Page 25: ... bps and then click START The COM port varies from computer to computer Figure 6 3 Verify COM Port and Baud Rate The Handshake icon below indicates a communication link between the Pan Tilt motor and the PC has been established Figure 6 4 PTCR 20 Main Screen with Handshake 3 After testing and setup exit PTCR 20 disconnect the RS232 cable and reconnect the green terminal blocks in the PSU Contact a...

Page 26: ...mera Control In the software click the Jog Limits button Use the SL soft limit Override button as needed Use the track pad to the left of the Set Soft Limit controls to move the camera to the appropriate soft limit position The Set Soft Limit buttons correspond to the direction applied on the track pad For example click the U direction on the track pad until the camera has reached the desired soft...

Page 27: ...t side of the software screen show a yellow or red color if a positional soft limit or hard limit has been reached During motor movement the appropriate circle will be green Figure 6 8 Positional Soft and Hard Limits In the dial feedback only the inner colored donut circle is of interest Red denotes an out of bounds area a limit and green denotes a free moving area Figure 6 9 Feedback Dials ...

Page 28: ...Limit to set the Down Soft Limit The motor s downward direction Soft Limit has now been set Repeat for the Up Soft Limit The same goes for setting the soft limits on the keyboard Position the camera unit to the desired up view by pushing down on the joystick Programming preset 38 will set Up Soft Limit and programming preset 37 will set Down Soft Limit The soft limit is independent of the path tak...

Page 29: ...0 telemetry on indicator indicates telemetry status set to ON LED8 Aux 8 SLED telemetry on indicator indicates telemetry status set to ON LED9 Auxiliary board power input indicator LED10 RS485 422 data input indicator constantly on in SELF TEST mode Flashing when receiving data LED11 Power input to SLED current control boards LED12 24 VDC system power indicator LED13 Aux 7 ZX700 power on indicator...

Page 30: ...m communication from controller required for both simplex 2 wire configuration and duplex 4 wire configuration T2 connects to system output to send system communication to controller OPTIONAL required only for duplex 4 wire configuration LED10 indicates communication traffic to the system LED always on when diagnostics function engaged 6 2 5 Self Test Diagnostic Function DIP1 Switch 6 Switch ON an...

Page 31: ...ard only on Camera Control board 6 3 5 Aux 5 Lens IR Correction Mode LED5 IR correction mode indicator LED5 ON lens IR correction enabled LED5 OFF lens IR correction disabled Default IR correction disabled 6 3 6 Aux 6 Camera Color Mono Mode LED6 camera mode indicator LED6 ON monochrome mode on LED6 OFF color mode on Default color mode 6 3 7 Aux 7 ZX700 IR On Off Control LED7 ZX700 on off indicator...

Page 32: ... Default LED12 on when system powered Voltage should read 24 VDC 0 7 VDC 6 4 3 T5 ZX700 Illuminator Output LED13 indicates power to both ZX700 LED13 ON power output to ZX700 IR units on LED13 OFF power output to ZX700 IR units off Default LED13 off power to ZX700 units off Voltage should read 27 VDC 0 7 VDC 6 4 4 T6 SLED 1 Power Output Indicator LED14 indicates power to SLED 1 LED14 ON power outpu...

Page 33: ...r indicator LED7 Aux 5 IR correction mode indicator used with LED3 LED8 Aux 4 iris control mode indicator CN1 Aux 1 control connection to lens CN2 Aux 4 control connection to lens CN3 Aux 6 control relay to camera CN4 12 VDC power input connection CN5 Firmware programming connection CN6 Aux 2 connection to wiper CN7 Aux 2 24 V connection for wiper park position CN8 Aux 5 control connection to lens...

Page 34: ...3 Camera Control Power Indicator LED6 indicates presence of power LED6 ON camera control board power on LED6 OFF camera control board power off Default LED6 on when system powered CN4 connects to 12VDC for power input 6 5 4 Address Selection DIP1 Switches 1 4 Switches in various combinations of on off will allow address setting of 1 16 Default address 1 Address MUST be the same for Auxiliary Contr...

Page 35: ...ol mode indicator LED8 ON manual iris control mode LED8 OFF auto iris control mode Default auto iris control mode CN2 connection to lens Upon initialization iris is fully closed 6 6 5 Aux 5 Lens IR Correction Mode LED3 and LED7 lens IR correction mode indicator LED3 ON lens IR correction enabled LED3 OFF lens IR correction disabled visible light mode Default LED3 and LED7 off CN8 connection to len...

Page 36: ...36 en Test Software Global View Station 1000 F 01U 173 867 2 0 2010 11 Operations Manual Bosch Security Systems Inc ...