32
en | Test Software
Global View Station 1000
F.01U.173.867 | 2.0 | 2010.11
Operations Manual
Bosch Security Systems, Inc.
6.4
Voltage Touch Points
6.4.1
T3 SLED Power Input Indicator
–
LED11 – indicates SLED controller power (not actual on/off state of illuminators)
–
LED11 ON = SLED controller power on
–
LED11 OFF = SLED controller power off
–
Default: LED11 on (when system powered)
–
Voltage should read 18 VDC ± 0.5 VDC
6.4.2
T4 Auxiliary Control Power Indicator
–
LED12 – indicates system power
–
LED12 ON = auxiliary board power on
–
LED12 OFF = auxiliary board power off
–
Default: LED12 on (when system powered)
–
Voltage should read 24 VDC ± 0.7 VDC
6.4.3
T5 ZX700 Illuminator Output
–
LED13 – indicates power to both ZX700
–
LED13 ON = power output to ZX700 IR units on
–
LED13 OFF = power output to ZX700 IR units off
–
Default: LED13 off (power to ZX700 units off)
–
Voltage should read 27 VDC ± 0.7 VDC
6.4.4
T6 SLED #1 Power Output Indicator
–
LED14 – indicates power to SLED #1
–
LED14 ON = power output to SLED #1 on
–
LED14 OFF = power output to SLED #1 off
–
Default: LED14 off (power to SLED #1 off)
–
Voltage should read 15 VDC ± 0.7 VDC
6.4.5
T7 SLED #2 Power Output Indicator
–
LED15 – indicates power to SLED #2
–
LED15 ON = power output to SLED #2 on
–
LED15 OFF = power output to SLED #2 off
–
Default: LED15 off (power to SLED #2 off)
–
Voltage should read 15 VDC ± 0.7 VDC