24
|
Information about the appliance
Greenstar
6 720 806 992 (2015/03)
3.17 Technical data combi boiler ZWB35-3A...
Input/Output
Unit
NG
LPG (propane)
Max. input rate 180/79 °F (82/26 °C)
BTU/hr (kW)
131,900 (38.6)
129,100 (37.8)
Max. output rate 104/86 °F (40/30 °C)
BTU/hr (kW)
122,800 (36.0)
122,800 (36.0)
Max. output rate 122/86 °F (50/30 °C)
BTU/hr (kW)
121,800 (35.7)
121,800 (35.7)
Max. output rate 176/140 °F (80/60 °C)
BTU/hr (kW)
116,700 (34.2)
116,700 (34.2)
Output rate domestic hot water (DHW), 113 °F (45 °C)
BTU/hr (kW)
120,500 (35.3)
120,500 (35.3)
Output rate domestic hot water (DHW), 140 °F (60 °C)
BTU/hr (kW)
118,700 (34.8)
118,700 (34.8)
Min. input rate 180/79 °F (82/26 °C)
BTU/hr (kW)
36,000 (10.5)
46,400 (13.6)
Min. output rate 104/86 °F (40/30 °C)
BTU/hr (kW)
35,100 (10.3)
46,100 (13.5)
Min. output rate 122/86 °F (50/30 °C)
BTU/hr (kW)
34,800 (10.2)
45,700 (13.4)
Min. output rate 176/140 °F (80/60 °C)
BTU/hr (kW)
31,700 (9.3)
42,000 (12.3)
Gas connection value
Natural Gas – H
s
= 1,010 BTU/ft
3
(37.3MJ/m
3
)
ft
3
/hr (m
3
/h)
130 (3.7)
–
Liquid Propane Gas – H
D-S
= 2,500 BTU/ft
3
(93.1MJ/m
3
)
ft
3
/hr (m
3
/h)
–
52 (1.5)
Permissible inlet gas pressure
NG
in. W.C. (mbar)
3.5-10.5" (8.7-26.1)
–
LPG (propane)
in. W.C. (mbar)
–
8-13" (19.9-32.3)
Expansion vessel
Pre-charge pressure
psi (bar)
10.9 (0.75)
10.9 (0.75)
Total contents
Gal (L)
3.17 (12)
3.17 (12)
DHW
Max. DHW flow rate
gpm (l/min)
3.17 (12)
3.17 (12)
Nominal DHW flow rate (at 140 °F (60 °C) outlet temperature)
gpm (l/min)
2.6 (10)
2.6 (10)
Outlet temperature
°F ( °C)
104 - 140 (40 - 60)
104 - 140 (40 - 60)
Max. cold water inlet temperature
°F ( °C)
140 (60)
140 (60)
Max. approved DHW pressure
psi (bar)
150 (10.3)
150 (10.3)
Minimum water pressure
psi (bar)
4.35 (0.3)
4.35 (0.3)
Flue gas
Flue gas mass flow at maximum/minimum nominal output
gps
15.7/4.5
15.2/5.6
Flue gas temperature 176/140 °F (80/60 °C) at maximum/minimum nominal
heat input
°F ( °C)
162/135 (72/57)
162/135 (72/57)
Flue gas temperature 104/86 °F (40/30 °C) at maximum/minimum nominal
heat input
°F ( °C)
127/91 (53/33)
127/91 (53/33)
CO
2
at max. nominal output
%
9.4
11.0
CO
2
at minimum nominal output
%
8.6
10.4
Condensate
Max. condensate quantity (t
R
= 86 °F (30 °C))
gph (l/h)
0.8 (3.1)
0.8 (3.1)
pH level, approx.
–
4.8
4.8
General
Voltage
VAC
120
120
Frequency
Hz
60
60
Max. power consumption (central heating mode)
W
205
205
Max. power consumption (Stand-by)
W
< 6
< 6
Sound pressure level
dB(A)
44
44
Max. supply temperature
°F ( °C)
190 (88)
190 (88)
Max. permissible operating pressure (P
MS
) heating
psi (bar)
30 (2.07)
30 (2.07)
Permissible ambient temperature
°F ( °C)
32 - 122 (0 - 50)
32 - 122 (0 - 50)
Nominal water capacity (heating)
Gal (L)
0.925 (3.5)
0.925 (3.5)
Weight (without packaging)
lbs. (kg)
110.2 (50)
110.2 (50)
Dimensions, W x H x D
inch
(mm)
17-21/64" × 33-15/32" × 13-57/64"
(440 × 850 × 353)
Table 9 Technical data combi boiler ZWB35-3A...