![Bosch GPB 12V-10 Professional Original Instructions Manual Download Page 13](http://html.mh-extra.com/html/bosch/gpb-12v-10-professional/gpb-12v-10-professional_original-instructions-manual_48394013.webp)
English |
13
Bosch Power Tools
1 609 92A 2NA | (29.7.16)
Assembly
Power Supply of the Construction Site Radio
The power supply of the construction site radio can take place
via the power-supply plug
24
or via a lithium-ion battery
15
.
Operation with Battery Pack
Note:
Use of batteries not suitable for the construction site ra-
dio can lead to malfunctions of or cause damage to the con-
struction site radio.
Note:
The battery pack is supplied partially charged. To en-
sure full capacity of the battery pack, completely charge the
battery pack in the battery charger before using for the first
time.
Use only the chargers listed in the technical data.
Only
these chargers are matched to the lithium-ion batteries
permitted for use in your construction site radio.
The lithium-ion battery can be charged at any time without re-
ducing its service life. Interrupting the charging procedure
does not damage the battery.
Insert a battery into the battery port
17
in such a manner that
the connections of the battery face against the connections in
the battery port
17
, and allow the battery to engage in the bat-
tery port.
The battery charge-control indicator
b
appears on the display
as soon as a battery pack with sufficient voltage is inserted
and the construction site radio is not connected to the mains
supply via the power-supply plug
24
.
The battery charge-control indicator
b
indicates the current
battery pack status. When the battery charge-control indica-
tor flashes, the battery pack must be charged.
To remove the battery pack
15
, press the unlocking buttons
16
and pull the battery pack out of the battery port
17
.
Operation with Power-supply Plug
Observe the mains voltage!
The voltage of the power
source for the power-supply plug must correspond with
the data on the type plate of the power-supply plug.
Open the protective cap of the 12 V connection socket
23
. In-
sert the plug-in connector
25
of the 12 V power-supply plug
into the 12 V connection socket
23
. Connect the power-sup-
ply plug to the mains supply.
Use only the original Bosch power-supply plug intend-
ed for your construction site radio.
This measure will en-
sure proper operation of the construction site radio.
After removing the plug-in connector, reattach the protective
cap of the 12 V connection socket
23
to protect against
dirt/debris.
When not using the power-supply plug
24
, it can be stored in
the storage compartment of the construction site radio. For
this, disengage the locking latch
21
and open the lid
20
of the
storage compartment.
Inserting/Replacing the Back-up Battery
In order to store the time in the construction site radio, back-
up batteries have to be inserted. Using alkali-manganese bat-
teries is recommended for this purpose.
To open the battery compartment, loosen screw
18
and re-
move battery lid
19
. Insert the back-up batteries. When in-
serting, pay attention to the correct polarity according to the
representation on the outside of the battery lid.
Mount the battery lid
19
again and tighten it with screw
18
.
Replace the back-up batteries when the time indication
e
be-
comes weaker and the construction site radio no longer
stores the time.
Always replace all batteries at the same time. Only use batter-
ies from one brand and with the identical capacity.
Remove the back-up batteries from the construction
site radio when not using it for longer periods.
When
storing for longer periods, the back-up batteries can cor-
rode and discharge themselves.
Audio Operation/Radio
Operating voltage
– for operation with power-
supply plug
– for battery-pack opera-
tion
V
V
12
12
Rated output of amplifier
(for operation with power-
supply plug)
2 x 5 W
Reception range
– FM
– AM
MHz
kHz
87.5–108
531–1602
Power-supply plug
Article number
1 600 A00 0..
Input voltage
V~
100–240
Frequency
Hz
50/60
Input current
mA
500
Output voltage
V=
12
Output current
mA
1500
Weight according to
EPTA-Procedure 01:2014
kg
0.20
Protection class
/
II
Construction Site Radio
GPB 12V-10
1) depending on the battery pack being used
2) limited performance at temperatures <0 °C
Technical data determined with battery from delivery scope.
Indication
Capacity
2/3
1/3
<1/3
Reserve
Battery pack empty