-18-
Intended Use
The laser measure is intended for measuring distanc-
es, lengths, heights and clearances. The laser measure
is suitable for measuring indoors.
conditions, e.g., with extreme illumination or a badly
reflecting surface, the measuring range may be lim-
ited.
B
In favorable conditions, a deviation influence of ±0.05
mm/m must be taken into account. In unfavorable
conditions, e.g., with extreme illumination, badly re-
flecting surface or the room temperature deviating
heavily from 77 °F (25 °C), the maximum deviation
can be up to ±3.0 mm. Additionally, a deviation influ-
ence of 0.15 mm/m must be taken into account.
C
In the real time measuring function, the maximum
operating temperature is 104 °F (40 °C).
D
Non-conductive soiling only, whereby occasional
temporary conductivity caused by condensation is
expected.
E
Shut-off after approximately 5 minutes in the real
time measuring function
F
Bluetooth
®
deactivated
G
After user calibration at 0 ° and 90 °; An additional
grade error of ±0.01 °/degree to 45 ° (max.) has to be
taken into account.
H
Left side of the tool is the reference side for inclination
measurement.
I
At 77 °F (25 °C ) operating temperature.
J
Bluetooth® devices must support the GATT profile.
The laser measure can be clearly identified with the
serial number (11) on the type plate.
2610059289 01-21 GLM165-G.indd 18