-15-
Model Number
. . . . . . . . . . . . . . . . . . .
GLL 100 G / GLL 100 GX
Article number
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
0601063P1X
Working range
1)
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 100 ft (30 m)
Leveling Accuracy . . . . . . . . . . . . . . . . . . . ±1/8 @ 33 ft (3 mm @ 10 m)
Self-leveling range, typically . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ±4°
Leveling duration, typically . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . < 4 s
Operating temperature . . . . . . . . . . . 14° F to 122° F (-10° C to +50° C)
Storage temperature . . . . . . . . . . . . . -4° F to 158° F (-20° C to +70° C)
Relative air humidity, max. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 90%
Laser class . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
Laser type . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 500-540 nm, <10 mW
C
6
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
Divergence. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 50X10 mrad (full range)
Tripod mount . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1/4”, 5/8”
Batteries. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 x 1.5 V LR06 (AA)
Operating duration in operating mode
Cross-line operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 h
Line operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12 h
Weight . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1.08 lbs (0.49 kg)
Dimensions . . . . . . . . . . . . . . . . . 4.4 x 2.2 x 4.2 in (112 x 55 x 116 mm)
Degree of protection . . . . . . . . IP 54 (dust and splash water protected)
The tool can be clearly identified with the serial number on the type plate.
1)
The working range can be decreased by unfavorable environmental
conditions (e.g. direct sun exposure).
Technical Data
Summary of Contents for GLL 100 G
Page 2: ... 2 GLL 100 G GLL 100 GX 9 10 1 1 1 8 1 2 8 Off 5 6 7 3 4 11 12 5 0 0 5 4 0 ...
Page 3: ... 3 C B A 13 ...
Page 4: ... 4 F E D G 14 15 ...
Page 5: ... 5 D1 F1 H I ...
Page 6: ... 6 B2 C2 D2 F2 ...