![Bosch GKS Professional 85 Original Instructions Manual Download Page 18](http://html.mh-extra.com/html/bosch/gks-professional-85/gks-professional-85_original-instructions-manual_49362018.webp)
18
| English
1 609 92A 14V | (10.2.15)
Bosch Power Tools
Adjusting the Riving Knife (GKS 85 G)
(see figure B)
Before any work on the machine itself, pull the mains
plug.
Always work with the riving knife, except when carry-
ing out plunge cuts.
The riving knife prevents jamming of
the saw blade while sawing.
Adjustment is carried out at minimal cutting depth, see “Ad-
justing the Cutting Depth”, page 18.
It is best to place the machine on the face side of the blade
guard
1
.
Loosen the clamping lever
28
, pull the saw away from the
base plate
14
and then tighten the clamping lever
28
again.
Loosen screw
25
, adjust the riving knife
13
to the measure
shown in the figure and tighten screw
25
with a tightening
torque between 8–9 Nm.
Disassembly/Assembly of the Riving Knife
For disassembly of the riving knife
13
, loosen screw
25
and
remove the riving knife
13
.
For assembly, insert the riving knife
13
and tighten it with the
screw
25
. Afterwards, check the adjustment of the riving
knife as described previously.
Dust/Chip Extraction
Before any work on the machine itself, pull the mains
plug.
Dusts from materials such as lead-containing coatings,
some wood types, minerals and metal can be harmful to
one’s health. Touching or breathing-in the dusts can cause
allergic reactions and/or lead to respiratory infections of
the user or bystanders.
Certain dusts, such as oak or beech dust, are considered
as carcinogenic, especially in connection with wood-treat-
ment additives (chromate, wood preservative). Materials
containing asbestos may only be worked by specialists.
– As far as possible, use a dust extraction system suitable
for the material.
– Provide for good ventilation of the working place.
– It is recommended to wear a P2 filter-class respirator.
Observe the relevant regulations in your country for the mate-
rials to be worked.
Prevent dust accumulation at the workplace.
Dusts can
easily ignite.
Mounting the Extraction Adapter (see figure C)
GKS 85:
Attach the extraction adapter
26
onto the chip ejector
17
un-
til it latches. Secure the extraction adapter
26
additionally
with the screw
27
.
A vacuum hose with a diameter of 35 mm can be connected to
the extraction adapter
26
.
GKS 85 G:
Attach the extraction adapter
26
onto the chip ejector
17
un-
til it latches. A vacuum hose with a diameter of 35 mm can be
connected to the extraction adapter
26
.
The extraction adapter may not be mounted when no
external dust extraction is connected.
Otherwise the ex-
traction channel can become clogged.
Do not connect a dust bag to the extraction adapter.
Otherwise the extraction system can become clogged.
To ensure optimum extraction, the extraction adapter
26
must be cleaned regularly.
External Dust Extraction
Connect the vacuum hose
33
to a vacuum cleaner (accesso-
ry). An overview for connecting to various vacuum cleaners
can be found at the end of this manual.
The machine can be plugged directly into the receptacle of a
Bosch all-purpose vacuum cleaner with remote starting con-
trol. The vacuum cleaner starts automatically when the ma-
chine is switched on.
The vacuum cleaner must be suitable for the material being
worked.
When vacuuming dry dust that is especially detrimental to
health or carcinogenic, use a special vacuum cleaner.
Operation
Operating Modes
Before any work on the machine itself, pull the mains
plug.
Adjusting the Cutting Depth (see figure D)
Adjust the cutting depth to the thickness of the work-
piece.
Less than a full tooth of the blade teeth should be
visible below the workpiece.
Loosen the clamping lever
28
. For a smaller cutting depth,
pull the saw away from the base plate
14
; for a larger cutting
depth, push the saw toward the base plate
14
. Adjust the de-
sired cutting depth at the cutting-depth scale. Tighten the
clamping lever
28
again.
The tightening tension of the clamping lever
28
can be read-
justed. For this, unscrew the clamping lever
28
, and screw it
back again turned offset by at least 30° in anticlockwise direc-
tion.
Adjusting the Cutting Angle
It is best to place the machine on the face side of the blade
guard
1
.
Loosen the wing bolts
8
and
16
. Tilt the saw sidewards. Ad-
just the desired measure on the scale
6
. Tighten the wing
bolts
8
and
16
again.
Note:
For bevel cuts, the cutting depth is smaller than the set-
ting indicated on the cutting-depth scale
29
.
Cutting Marks
The 0° cutting mark (
9
) indicates the position of the saw blade
for straight cuts. The 45° cutting mark (
10
) indicates the po-
sition of the saw blade for 45° cuts without using the guide
rail.
OBJ_BUCH-293-007.book Page 18 Tuesday, February 10, 2015 8:40 AM