English |
17
Bosch Power Tools
1 609 929 W90 | (25.10.10)
Setting the Temperature
The temperature can only be regulated in the
hot-air stage .
To increase the temperature, press on the
“+”
of
the temperature-control button
9
, to decrease
the temperature, press on the
“–”
.
Briefly pressing the temperature-control button
9
at the respective position increases or de-
creases the temperature by 10 °C. Prolonged
pressing of the temperature-control button con-
tinuously increases or decreases the tempera-
ture by 10 °C, until the button is released or the
maximum or minimal temperature is reached.
After a change to the temperature setting, the
power tool requires a short period to warm up
or cool down the air flow. During this period, the
target temperature is indicated between the
flashing arrows in the display
7
. When the target
temperature is reached, the arrows go out and
the display indicates the actual temperature.
Activating/Deactivating the Button Lock (“LOC”)
To prevent accidental changing of the air flow
and temperature the function of buttons
6
,
8
,
9
and
10
can be locked when in the hot-air
stage. In the cool-air stage the air flow can be
changed even when the button lock is activated.
Activating the Button Lock:
Switch the power tool on while in the hot-air
stage . Adjust the air-flow and temperature set-
tings to be locked.
Switch the power tool off.
Press and hold the save button
10
and switch
the power tool on again (in cool-air or hot-air
stage). The display
7
will indicate
“OFF”
for the
deactivated button lock.
With the save button
10
still held, press one after
the other:
–
“+”
on the temperature-control button
9
,
–
“+”
on the air-flow control button
8
,
–
“–”
on the temperature-control button
9
,
–
“–”
on the air-flow control button
8
.
The display indicates
“ON”
. Release the save
button
10
.
The button lock is now activated. The preset val-
ues for temperature and air flow are indicated in
the hot-air stage . After pushing any button,
“LOC”
is indicated in the display and the values
cannot be changed.
Deactivating the Button Lock:
Switch the power tool off. Push and hold the
save button
10
and switch the power tool on
again. The display indicates
“ON”
for the acti-
vated button lock. Push the temperature button
9
and the air-flow control button
8
in the same
sequence as when activating the button lock.
The display indicates
“OFF”
for the deactivated
button lock.
Operating Modes
Cool-air Stage
The air flow can be regulated, the
temperature is set to 50 °C (cannot
be regulated), and programming op-
eration is not possible.
The cool-air stage is suitable for cooling down
a heated-up workpiece or for drying paint. It is
also suitable for cooling down the power tool
before placing it down or changing nozzles.
When changing from the hot-air stage with
higher temperatures, it will take a few moments
until the power tool has cooled down to 50 °C.
During cooling down, the display
7
indicates the
actual temperature at the nozzle outlet.
When changing from the hot-air stage to the
cool-air stage , the current air-flow settings
are taken over.
Hot-air Stage
The air flow and temperature can be
regulated; normal and programming
operation are possible.
When changing from the cool-air stage to the
hot-air stage , the air flow, temperature and
possibly the program are automatically adjusted
according to the settings of the last hot-air stage
operation.