74
en | Setting up VCA
Camera Browser Interface
AM18-Q0611 | v5.50 | 2012.03
Software manual
Bosch Security Systems
Appearing edges
Select this option if the selected area of the reference image
includes a largely homogenous surface. If structures appear in
this area, then an alarm is triggered.
Selecting the area
Select the image areas in the reference image that are to be
monitored. The video image is subdivided into square fields.
Activate or deactivate each of these fields individually.
Select only those areas for reference monitoring in which no
movement takes place and that are always evenly lit, as false
alarms could otherwise be triggered.
1.
Click
Select Area
to configure the sensor fields. A new
window opens.
2.
If necessary, click
Clear All
first to clear the current
selection (fields marked yellow).
3.
Left-click the fields to be activated. Activated fields are
marked yellow.
4.
If necessary, click
Select All
to select the entire video-
frame for monitoring.
5.
Right-click any fields to deactivate.
6.
Click
OK
to save the configuration.
7.
Click the close button (
X
) in the window title bar to close
the window without saving the changes.