1 689 989 411
2019-04-01
|
Robert Bosch GmbH
Product description | FSA 500 | 23
en
3.5.3
Connection panel FSA 500
DANGER – Risk of electric shock from ex-
cessively high measurement voltage!
The measurement of voltages in excess of
200 V using CH1 / CH2 multi measurement
cables will result in injury, heart failure or
fatal electric shocks.
¶
CH1 / CH2 multi measurement cables are
only to be used for measuring voltages up
to max. 200 V.
¶
Never use CH1 / CH2 multi measurement
cable to measure mains or similar volta-
ges.
10
9
8
7
6
5
4
3
2
1
459903-02_Ko
11
Fig. 2:
Connection panel FSA 500 (viewed from underneath)
Item
Color code
Connection
2)
1
Red/black
Battery B+/B‒ cable
(battery B– cable for vehicle
ground)
2
Green or
white or yel-
low
Secondary measuring sensor or 30 A
amps clamp or 1000 A amps clamp
or adapter cable 1 681 032 098 with
fluid pressure sensor (both special
accessories)
3
Green or red
or yellow
CH2 multi measurement cable
or 30 A amps clamp or
1000 A amps clamp
4
Green or blue
or yellow
CH1 multi measurement cable
or 30 A amps clamp or
1000 A amps clamp
5
-
Coupling with hose assembly (at-
mospheric pressure measurement)
6
-
Remote trigger
7
White/black
Clip-on sensor or adapter cable
1 684 465 513 for clip-on sensor1)
8
Blue/white
Oil temperature sensor, air and IR
temperature sensor (special acces-
sories)
9
Yellow / green Connecting cable term. 1/term.
15/EST/TN/TD
10
-
Power supply port
11 -
-
Connection for charging station
(special accessory)
1)
For speed measurements with a clip-on sensor, the adapter cable
1 684 465 513 must always be connected between the FSA 500
socket (item 7) and the connection cables for the clip-on sensor.
2)
The color codings on the connection cables refer to the correct
connection at the FSA 500.
3.5.4
LED Indicators
LED A: Status light
State
LED A
Not lit
FSA 500 off.
Red light
The FSA 500 starts up.
Flashing
white
(1 Hz)
FSA 500 on, but not yet ready for operation.
No data link with PC/Laptop.
Flashing
green
(1 Hz)
FSA 500 is ready for operation.
Data link to PC/Laptop established via USB.
Flashing
blue
(1 Hz)
FSA 500 is ready for operation.
Data link to PC/Laptop established via Bluetooth.
Flashing
red
(4 Hz)
Firmware error.
FSA 500 not ready for use.
LED B: Charge indicator
State
LED B
Measure
Not lit
No external power sup-
ply connected. Voltage
supply via battery.
-
Violet light External voltage sup-
ply connected. Storage
battery being charged.
-
Blue light
External voltage sup-
ply connected. Storage
battery is charged.
External voltage supply
can be disconnected.
Red light
External voltage supply
connected.
Possible cause of trou-
ble:
R
Battery temperature
>45 °C
R
Storage battery not
connected
R
Battery defective
R
Plug defective
Check storage battery
and plug.
Allow the FSA 500 to
cool down.
3.5.5
Remote trigger
The start soft key (F3) or the stop soft key (F4) in the
FSA 500 CompacSoft [plus] software can be activated
with the button on the remote trigger.
1
2
459903-04_Ko
Fig. 3:
Remote trigger (1 684 463 828)
1 Key
2 Connector for FSA 500
i
For connection see fig. 2, item 6.