16
en | Preparing for installation
FLEXIDOME IP starlight 8000i
2021-02 | V02 | F.01U.385.211
Installation manual
Bosch Security Systems B.V.
Audio I/O
Connect audio devices to the audio input and audio output connectors.
The unit has full-duplex mono audio for two-way communication between a speaker or door
intercom system. The audio input signal is transmitted in synchronization with the video
signal.
1.
Input:
Line input level (not suitable for direct microphone signal); impedance 18 kOhm typical;
1 Vrms maximum input voltage.
2.
Output:
Line output level (not suitable for direct speaker connection); impedance 1.5 kOhm
minimum; 0.85 Vrms maximum output voltage.
Use shielded audio connection cable with advised maximum cable lengths for audio line input
and output levels.
4.3.4
Grounding
The camera is double-insulated and does not need a safety earth connection, but grounding is
recommended for outdoor applications.
Grounding provides improved surge protection (up to 1 kV, 2 kA to ground (8/20 µs pulse)).
The grounding wire is not included in the box. Bosch recommends the use of a grounding wire
with a ring terminal.
The ring terminal must not have a thickness greater than 2 mm (0.01 in.).
i
Notice!
Use proper surge protection on cables that are routed outdoors, or close to large inductive
loads or electrical mains supply cables.