36
en | Technical data
Smoke Alarm
02.2016 | 3.2 | F.01U.309.849
Bosch Sicherheitssysteme GmbH
* high temperature (> +30 °C) reduce the battery lifetime
** during standard usage and operation as stated in the user guide
*** based on typical storage temperature (-5 … +30 °C) and typical
operating temperature (+5 … +30 °C) and monthly functional tests
Certification
CE, VdS, Q-Label
Harmonized standards
EN 14604:2009-02
Signals
Mode
Optical
Audible
Normal
-
-
Functional test OK
flashes red fast,
emergency light
3 x ≥85 dB(A)
Alarm
flashes red fast,
emergency light
3 x ≥85 dB(A) / 4 s
Muted
flashes red 1 x / 10 s for
10 min
-
Weak battery
flashes red 1 x / 43 s
1 x short / 43 s
Polluted smoke
chamber
flashes red 3 x / 43 s
3 x short / 43 s
Alarm reset,
automatically
flashes red 1 x / 43 s for
24 h
-