Necessary
tools:
Cross-tip screwdriver
Drill-driver
14
Fan 1500, Fan 1500 DH
Applicable to the DH version:
Set the stop delay time and sensitivity of the humidity sensor using the
button (7) and the potentiometer on the controller (8).
• Place the cover (2) on the middle of the bathroom extractor fan housing (5) and screw it with screws (3).
• Check the tightness of the power cord.
- The power cord must be secured in such a way that, in the event of flooding, no water can enter the
live parts along the cable.
• Install the front panel (1) as a protection against contact with moving parts.
• The fan is designed to be mounted both horizontally and vertically on a ventilation shaft or pipe of
suitable diameter. In the case of vertical installation, the fan must be protected against precipitation
and condensate. It is not permitted to install a fan with a direct upward air discharge.