EX7-IP
| en
3
Bosch Security Systems
Quick Install
MAN7IPB Rev.0 | 2008.10
The full version Installation Manual is available on the enclosed CD-ROM and can
be viewed and printed out with Acrobat Reader, which is also on the enclosed
CD-ROM. This user guide is the intellectual property of BOSCH Security Systems
and is protected by copyright
!
CAUTION!
–
Camera Grounding -
For mounting the camera in potentially
damp environments, ensure to ground the system using the
ground connection of the power supply connector (see section:
Connecting external power supply).
–
U.S.A. models only -
Section 810
of the
National Electrical
Code, ANSI/NFPA No.70
, provides information regarding proper
grounding of the mount and supporting structure, grounding of
the coax to a discharge unit, size of grounding conductors, loca-
tion of discharge unit, connection to grounding electrodes, and
requirements for the grounding electrode.
–
Permanently connected equipment -
Incorporate a readily
accessible disconnect device in the building installation wiring.
–
Power lines -
Do not locate the camera near overhead power
lines, power circuits, or electrical lights, nor where it may contact
such power lines, circuits, or lights.