background image

EX7-IP

 | en

1

Bosch Security Systems

Quick Install

 MAN7IPB Rev.0 | 2008.10

Important safety instructions

Type numbers: NEC-070V04-11 |NEN-070V04-11 |NEC-070V04-21 
NEN-070V04-21 INEC-070V05-11 |NEN-070V05-11 |NEC-070V05-21 
NEN-070V05-21 INEC-070V09-11 |NEN-070V09-11 |NEC-070V09-21 
NEN-070V04-21

Read, follow, and retain all of the following safety instructions. Heed all warnings on 

the unit and in the operating instructions.
1. 

Cleaning - Unpower the unit before cleaning. Follow any instructions provided 
with the unit. Generally, using a dry cloth for cleaning is sufficient, but a moist 
fluff-free cloth or leather shammy may also be used. Do not use liquid 
cleaners or aerosol cleaners.

2. 

Heat Sources - Do not install the unit near any heat sources such as radiators, 
heaters, stoves, or other equipment (including amplifiers) that produce heat.

3. 

Object and liquid entry - Never push objects of any kind into this unit through 
openings as they may touch dangerous voltage points or short-out parts that 
could result in a fire or electrical shock. Never spill liquid of any kind on the 
unit. Do not place objects filled with liquids, such as vases or cups, on the unit.

4. 

Controls adjustment - Adjust only those controls specified in the operating
instructions. Improper adjustment of other controls may cause damage to the 
unit. Use of controls or adjustments, or performance of procedures other than 
those specified, may result in hazardous radiation exposure.

5.

Overloading - Do not overload outlets and extension cords. This can cause 
fire or electrical shock.

6.

Power sources - Operate the unit only from the type of power source indicated 
on the label. Before proceeding, be sure to disconnect the power from the 
cable to be installed into the unit.

- For external power supplied units, use only the recommended or approved 

power supplies.

- For limited power source units, this power source must comply with 

EN60950

. Substitutions may damage the unit or cause fire or shock.

- For 24 VAC units, voltage applied to the unit's power input should not 

exceed 24 VAC. User-supplied wiring must comply with local electrical 
codes (Class 2 power levels). Do not ground the supply at the terminals or 
at the unit's power supply terminals.

- If unsure of the type of power supply to use, contact your dealer or local 

power company.

7.

Damage requiring service - Unplug the unit from the main AC power source 
and refer servicing to qualified service personnel when any damage to the 
equipment has occurred, such as:

- the power supply cord or plug is damaged;

Summary of Contents for EX7-IP

Page 1: ...EX7 IP Ceiling Mounted No Grip IP Camera EX7 IP en Installation Manual ...

Page 2: ......

Page 3: ... Controls adjustment Adjust only those controls specified in the operating instructions Improper adjustment of other controls may cause damage to the unit Use of controls or adjustments or performance of procedures other than those specified may result in hazardous radiation exposure 5 Overloading Do not overload outlets and extension cords This can cause fire or electrical shock 6 Power sources O...

Page 4: ...y use attachments accessories specified by the manufacturer Any change or modification of the equipment not expressly approved by Bosch could void the warranty or in the case of an authorization agreement authority to operate the equipment i o DANGER High risk This symbol indicates an imminently hazardous situation such as Dangerous Voltage inside the product If not avoided this will result in an ...

Page 5: ...er supply connector see section Connecting external power supply U S A models only Section 810 of the National Electrical Code ANSI NFPA No 70 provides information regarding proper grounding of the mount and supporting structure grounding of the coax to a discharge unit size of grounding conductors loca tion of discharge unit connection to grounding electrodes and requirements for the grounding el...

Page 6: ...port Power supply 1 2 Initial Preparations 1 Determine the operating voltage at the installation site The camera s Voltage Regulator Board accepts 12 24VAC VDC input without change to internal connections 2 Determine the optimum mounting location for the camera See Section 2 Mounting the unit 3 All cameras have been tested and pre focused with telephoto setting as factory default prior to shipment...

Page 7: ...from the chassis assembly ensuring the wires are not displaced and the camera lens is not damaged 2 2 Camera Mounting and setup Select a suitable location that protects the camera from accidental damage tampering and environmental conditions exceeding the specifications of the camera to be mounted CAUTION Ensure the selected location is protected from falling objects accidental contact with moving...

Page 8: ... 8 drywall nylon plugs or a superior connection 2 1 The mounting holes are configured for a single gang electrical box or a ceiling electrical box See the figure below for the mounting template 2 2 Ethernet connection 2 2 1 Connect the RJ45 cable not supplied to its mating connector See figure below on page 7 2 2 2 Feed the camera s power cable and the RJ45 cable through the foam gasket at the bot...

Page 9: ...EX7 IP en 7 Bosch Security Systems Quick Install MAN7IPB Rev 0 2008 10 2 3 Camera chassis mounting RJ45 mating connector ...

Page 10: ...cure all cabling Camera Setup To determine if the camera is receiving a picture 1 Make sure the supplied software is installed in your PC laptop computer For Camera Configuration and Software Viewing Setup refer to full version Installation Manual available on the enclosed CD ROM Section 4 2 Connect the camera to the PC laptop and power up the camera Follow the prompts See section 2 of full versio...

Page 11: ... to the inside face of the viewing window without touching For focus adjustment follow the steps below 1 Loosen the lens set screws for focus zoom adjustments 2 The set screw marked N is used for image focus 3 The set screw marked T W is used for telephoto or wide angle settings 4 Re tighten the set screws after focus adjustments have been com pleted 5 Locate the Auto Iris adjustment controls ...

Page 12: ...ditions on scene for correct 24 hour focusing For camera with manual iris lens the camera should be focused with the lens iris fully opened to simulate the worst possible depth of field Using a Infra Red Pass filter will ensure the iris is fully open for cor rect setup and adjustment Note that statement above is applicable only for Day Night or IR version cameras ...

Page 13: ......

Page 14: ...rica Bosch Security Systems B V P O Box 80002 5600 JB Eindhoven The Netherlands Phone 31 40 2577 284 Fax 31 40 2577 330 emea securitysystems bosch com www boschsecurity com Asia Pacific Bosch Security Systems Pte Ltd 38C Jalan Pemimpin Singapore 577180 Phone 65 6319 3450 Fax 65 6319 3499 apr securitysystems bosch com www boschsecurity com Bosch Security Systems Inc 2009 Data subject to change with...

Reviews: