22
en | Camera Configuration
EX14 Marine Camera
F.01U.240.878 | 1.0 | 2011.07
Instruction Manual
Bosch Security Systems, Inc.
E.SHUTTER
Select either AUTO or FIXED control for the electronic
shutter.
Note:
The default setting is AUTO. If you change this setting
undesired operation may occur.
AUTO
Set for complete automatic operation of the electronic
shutter, only available when lens iris control is set to Manual.
FIXED
Set the desired minimum shutter speed. Ten levels are
available.
1/50s(PAL), 1/60s(NTSC), 1/100s,1/250s, 1/500s, 1/1000s,
1/2000s, 1/4000s, 1/10000s, 1/100000s)