SIA Standard Audio Verification Commands (Item No. 168 = 0)
Phone Button
Command
Alternate Audio Verification Commands (Item No. 168 = 1)
Phone Button
Command
[#]
Talk to premises.
[*]
Listen to premises.
[7] (any number 1 to 9)
Restart 90-second timer.
[0]
Terminate session without call back.
Route Destination Items
Item
No.
Programming Item
Range
100
Account Number
4- or 6-digit number
201
Phone Line Supervision
0 = On
1 = Off
202
PSTN, IP or Cellular
Connection
0 = PSTN telephone line
1 = B426, B450
205
Dial Tone Detect
0 = On
1 = Off
Phone Number/IP Address for Route Destination:
206
Route 1 Primary
32 digits maximum
0-9, B-F allowed.
. = [*] (. between each IP address
notation).
Exit with save = [#]
Exit without save = [#][#]
Disable phone number = [0][#]
Disable IP address = 240.0.0.0
207
Route 1 Backup
208
Route 2 Primary
209
Route 2 Backup
210
SMS Service Provider No.
Format for Route Destination:
211
Route 1 Primary
0 = Disabled
1 = Contact ID
2 = SIA
3 = Voice
4 = SMS
5 = Fast Format
6 = Network
212
Route 1 Backup
213
Route 2 Primary
214
Route 2 Backup
215
Call Waiting Disable
3 or 4 digits
* = [*][*]; # = [*][#]
216
Emergency Call Override
No.
3-digit number
16