Control panel model 2

Setting the fan

Switching on

Touch the 

#

 symbol.

The fan will start at fan setting 2.

Selecting a fan setting

Select the fan setting.

Switching off

Touch the 

#

 symbol.

Intensive setting

You can use the intensive setting if there is a large 

build-up of odours and fumes/vapours.

Switching on

Touch the 

C

 or 

D

 symbol.

Note: 

After approx. 6 minutes, the extractor hood 

automatically switches back to fan setting 3.

Switching off

If you want to end intensive mode before the preset 

time expires, touch the symbol for the required fan 

setting.

Intermediate position for the glass front

On some appliances, the glass front can be adjusted to 

an intermediate position. The intermediate position can 

be used for eliminating particularly strong cooking 

smells and large amounts of steam. 
Take hold of the glass front in the centre and open it 

carefully.

Fan run-on time

Switching on

Touch the 

y

 symbol.

The fan will run at fan setting 1.
After approximately 10 minutes, the fan will switch itself 

off automatically.

Switching off

Touch the 

y

 symbol.

This immediately stops fan run-on.

Automatic mode

Switching on

1.

Touch the 

#

 symbol.

The fan will start at setting 2.

2.

Touch the 

>

 symbol.

The optimum fan setting is set automatically using 

the PerfectAir sensor.

Switching off

Touch 

#

 or any fan setting to switch off automatic 

mode.
The fan switches itself off automatically if the PerfectAir 

sensor detects no further change in the air quality in the 

room.
Automatic mode can run for a maximum of 4 hours.

Symbol

Explanation

#

Fan on/off

1-3

Fan settings

C

Intensive mode 1

D

Intensive mode 2

y

Fan run-on

>

Automatic mode

E

Metal grease filter saturation indicator

F

Activated charcoal filter saturation indicator

D

Home Connect

l

Decorative LED lighting

B

Light on/off/dimming

Summary of Contents for DWK98PR60

Page 1: ... en Instructions for installation and use Extractor hood ...

Page 2: ... its installation location This appliance is intended for domestic use and the household environment only The appliance is not intended for use outside Do not leave the appliance unattended during operation The manufacturer is not liable for damage which is caused by improper use or incorrect operation This appliance is intended for use up to a maximum height of 2000 metres above sea level This ap...

Page 3: ...ndows incoming exhaust air wall boxes or by other technical means In any case consult your responsible Master Chimney Sweep He is able to assess the house s entire ventilation setup and will suggest the suitable ventilation measures to you Unrestricted operation is possible if the vapour extractor hood is operated exclusively in the circulating air mode Warning Risk of fire Fatty deposits in the g...

Page 4: ...t the after sales service Risk of electric shock Incorrect repairs are dangerous Repairs may only be carried out and damaged power cables replaced by one of our trained after sales technicians If the appliance is defective unplug the appliance from the mains or switch off the circuit breaker in the fuse box Contact the after sales service Risk of electric shock Do not use any high pressure cleaner...

Page 5: ...modes Operatingmodes Exhaust air mode Note The exhaust air must not be conveyed into a functioning smoke or exhaust gas flue or into a shaft which is used to ventilate installation rooms which contain heat producing appliances Before conveying the exhaust air into a non functioning smoke or exhaust gas flue obtain the consent of the heating engineer responsible If the exhaust air is conveyed throu...

Page 6: ... approx 6 minutes the extractor hood automatically switches back to fan setting 3 Switching off If you want to end intensive mode before the preset time expires touch the symbol for the required fan setting Intermediate position for the glass front On some appliances the glass front can be adjusted to an intermediate position The intermediate position can be used for eliminating particularly stron...

Page 7: ... Metal grease filter and activated charcoal filter 1 and 2 If you have not yet done so the metal grease filters should now be cleaned or the activated charcoal filter replaced Cleaning and maintenance on page 13 The saturation indicators can be reset while they are flashing To do this touch the symbol Switching over the display for air recirculation mode For air recirculation mode the electronic c...

Page 8: ...arge amounts of steam Take hold of the glass front in the centre and open it carefully Fan run on time Switching on Touch the y symbol The fan will run at fan setting 1 After approximately 10 minutes the fan will switch itself off automatically Switching off Touch the y symbol This immediately stops fan run on Automatic mode Switching on 1 Touch the symbol The fan will start at setting 2 2 Touch t...

Page 9: ...ion mode the electronic controller must be switched over accordingly The extractor hood must be connected and switched off Touch and hold the D symbol Touch the 2 symbol Take your finger off the D symbol This will switch the electronic controller over to air recirculation mode filters that cannot be regenerated Touch and hold the D symbol Touch the 3 symbol Take your finger off the D symbol This w...

Page 10: ...ols on the hob Using the controls on the extractor hood always takes priority It is not possible to use the hood controls on the hob during this time Setting up a connection The hood must be switched off before you can connect the hob and extractor hood Connecting directly Make sure that the hob is switched on and is in search mode Refer to your hob s instruction manual for more information Notes ...

Page 11: ...e extractor hood to your home network the hood and the light must be switched off 1 Press and hold the D symbol until it starts to flash 2 Press 1 to start automatic login to your home network The LED for fan setting 1 and the D symbol will flash 3 Press the WPS button on the router within the next 2 minutes If the extractor hood has successfully connected it will automatically connect to the Home...

Page 12: ... automatically We recommend that you install security updates as soon as possible Resetting the connection You can reset the connections you have saved on your home network and on Home Connect at any time Press and hold the and D symbols until an audible signal sounds About data protection When your appliance is connected for the first time to a WLAN network which is connected to the Internet your...

Page 13: ...all purpose cleaning products Oven spray Note Wash new sponge cloths thoroughly before use Note Follow all instructions and warnings included with the cleaning products Removing metal grease filter 1 Open the glass front fully 2 Open the lock and swing down the metal grease filter When you do this take hold of the metal grease filter from underneath with your other hand 3 Take the metal grease fil...

Page 14: ... rinse them thoroughly Leave the metal grease filters to drain on an absorbent material In the dishwasher Note Slight discolouration may occur if the metal grease filters are cleaned in the dishwasher This discolouration has no effect on the performance of the metal grease filters Use normal domestic dishwashing detergents Do not clean heavily soiled metal grease filters together with cookware Pla...

Page 15: ...ructions apply to several appliance models It may be the case that an optional accessory that is listed does not apply for your appliance Note Observe the installation instructions in the accessory Problem Possible cause Solution The appliance does not work The plug is not plugged in Connect the appliance to the electricity supply Power cut Check whether other kitchen appliances are working Faulty...

Page 16: ...o be operated in air recirculation mode an optional accessory must be fitted To do this refer to the installation instructions provided The flue duct does not need to be fitted for air recirculation mode For additional optional accessories refer to the installation instructions provided The surfaces of the appliance are sensitive Avoid damaging them during installation PLQ PP PLQ PP PD PP PLQ PP P...

Page 17: ...tion Damage to the appliance The surfaces of the appliance are sensitive Avoid damaging them during installation The width of the extractor hood must correspond at least with the width of the hob For the installation observe the currently valid building regulations and the regulations of the local electricity and gas suppliers Warning Risk of fire Fatty deposits in the grease filter may catch fire...

Page 18: ...al vacuum in the place where the heat producing appliance is installed does not exceed 4 Pa 0 04 mbar This can be achieved when the air needed for combustion is able to enter through openings that cannot be sealed for example in doors windows incoming exhaust air wall boxes or by other technical means In any case consult your responsible Master Chimney Sweep He is able to assess the house s entire...

Page 19: ... KGeneral information Generalinformation Checking the wall The wall must be level vertical and adequately load bearing The depth of the bore holes must be the same length as the screws The wall plugs must have a secure grip The enclosed screws and wall plugs are suitable for solid brickwork Suitable fasteners must be used for other structures e g plasterboard porous concrete poroton bricks The max...

Page 20: ... hood should be positioned and lightly mark where the lower edge of the appliance should be on the wall Determine where the middle should be based on the hob Note We recommend fitting the extractor hood such that the lower edge of the glass screen is in line with the lower edges of the adjacent wall hung cabinets Make sure that the specified safety clearances from the hob are complied with 2 Place...

Page 21: ...Installation en 21 Fitting with a flue duct Fitting without a flue duct PP PP PP PP PP PP PP PP PP PP PP PP PP PP PP PP ...

Page 22: ...Hold the bracket firmly when doing so 5 If no duct is to be fitted screw in the two locking screws without the bracket Connecting the pipes If the extractor hood is to be operated in exhaust air mode the pipes must be connected If the extractor hood is to be operated in air recirculation mode an optional accessory must be fitted To do this refer to the installation instructions provided Note If an...

Page 23: ...tective film from both flue duct sections 3 Push one flue duct section into the other Notes To prevent scratches lay paper over the edges of the outer flue duct section to protect the surface The slots of the inner flue duct section point downwards 4 Place flue ducts sections on the appliance 5 Slide the inner flue duct section upwards attach it to the left and right sides of the retaining bracket...

Page 24: ...961001 9001159153 9001159153 Robert Bosch Hausgeräte GmbH Carl Wery Straße 34 81739 München Germany www bosch home com ...

Reviews: