DVR 600 Series firmware version history 

3.1

 

Version 1.1.0 

File name: 600series.bin (2010-11-30) 

 
Initial firmware version 
 

3.2

 

Version 1.2.0 

File name: 600series.bin (2011-03-28) 

 
This release includes the following improvement: 
-

 

PC application support (CC v3.32) of DVR 600 Series with firmware version 1.2.0. 

 

3.3

 

Version 1.3.2 

File name: 600series.bin (2011-09-27) 

 
This release includes the following improvement: 

 

Improve dome control using Intui keyboard. 

o

 

Immediate dome control when full screen is selected for cameras assigned for 
dome control. 

 

Quad image performance on Mon. A improved (diagonal lines were more jagged than in 
other multiscreens).  

 

Mon. B image performance improved (shown some flickering by certain monitor/camera 
combinations) 

 

Setting added to Auto delete video older than 3 days. For some countries this is required 
by law. 

 

SMTP port number was default on 587 when SSL is enabled. 

o

 

This port number is now user selectable. 

 
This release includes the following bug fixes were below issues are solved: 

 

In low or unstable network configurations the DVR sometimes block any network user 
access until the unit was power cycled.  

 

It was not possible to record a tour in G3 domes via DVR. 

 

DVR was losing network gateway in some network applications. 

 

Network connection was not possible immediately after network disconnect. 

 

DVR ID in web pages showed one number higher than set in DVR. 

 

DVR rebooted after a number of smart search actions in web interface. 

 

Summary of Contents for DVR 600 Series

Page 1: ... 650 Series recorders Bosch can no longer be held liable for any loss or damages or system mal function resulting from the use of non Bosch drives Bosch will provide advance exchange and carry in service only on Bosch products This means that failing DVR630 650 Series recorders should be returned for repair without non Bosch drives Should non Bosch hard disk drives be returned then Bosch will not ...

Page 2: ...R software In this case the current DVR settings and video will not be deleted or replaced during the update process Figure Update firmware menu 6 Select OK to begin the update process or click Cancel to stop and exit After the update process is completed you have to press OK so that the system will automatically restart Alternative a firmware upgrade can be performed via the Web Client Open Inter...

Page 3: ...mance on Mon A improved diagonal lines were more jagged than in other multiscreens Mon B image performance improved shown some flickering by certain monitor camera combinations Setting added to Auto delete video older than 3 days For some countries this is required by law SMTP port number was default on 587 when SSL is enabled o This port number is now user selectable This release includes the fol...

Page 4: ...ed user will be clearly notified when video format of DVR don t match with video format of connected cameras Improve PTZ handling in full screen you can select Menu Search Export or Exit when PTZ control is active Video playback from HDD mounted in other DVR600 possible to move complete HDD set from one to another DVR600 Avoid invalid log on when user ID is used special characters like In this fir...

Page 5: ...hich in the unlikely case of SW error triggers a restart to guarantee reliable operation throughout the units lifetime We recommend that customers update their DVR units to the newest FW to benefit from this protection layer 3 8 Version 2 0 5 File name 600series bin 2012 This release includes the following improvement Improve compatibility with Late Configuration tool version 2 7 No functional cha...

Page 6: ...in tools Internet options Security Custom level Miscellaneous Include local directory path when uploading files to a server Enable this setting to make uploading DVR400 600 firmware possible Note 3 The CC only shows maximum one event per second So if more events are generated within one second only the last event is shown On the local unit always all events are shown ...

Reviews: