background image

 

 

Product 

Document type 

Release # 

SAP/Doc number 

DVR 600 Series 

Release notes 

V2.0.6 

 

Video Recorder 600 Series new firmware version 

www.BoschSecurity.com 
 

 

 

 

 

Security Systems

 

Release date 

2012.10.12 
 

 

 

 

 

 

  

 

 

 

 

Page 1 of 6 

 

 

1

 

DVR 600 Series firmware version 2.0.6 (date 2012-10-12) 

 
File name: 600series.bin (2012-10-12) 

 
This release includes the following improvement: 

 

In this version unsigned hard disk drives are supported.  
The below drives are released and recommended for use in the DVR630/650. These are 
available from Bosch Security Systems as DVR-XSxx0-A Storage Expansion Kits.  
 
 
 
 
 
 
 
 
 
 
We do not test other drives than indicated above to verify reliability: 

 

When using non-Bosch drives in DVR630/650 Series recorders, Bosch can no 

longer be held liable for any loss or damages or system mal-function resulting 

from the use of non-Bosch drives.  

 

Bosch will provide advance exchange and carry in service only on Bosch 

products. This means that failing DVR630/650 Series recorders should be 

returned for repair without non-Bosch drives. 

 

Should non-Bosch hard disk drives be returned, then Bosch will not be held 

responsible for loss of these drives or any information recorded on these drives 

or for any consequential damages. 

 

Bosch will not be held liable for loss or consequential damages resulting from 

disclosure of any information stored on these non-Bosch drives.  

 

 

Remote export on low bandwidth networks are supported in this version. 

 

Bosch strongly recommends upgrading to the latest firmware to 

achieve the best possible functionality, compatibility and 

performance.

 

 

 

Summary of Contents for DVR 600 Series

Page 1: ... 650 Series recorders Bosch can no longer be held liable for any loss or damages or system mal function resulting from the use of non Bosch drives Bosch will provide advance exchange and carry in service only on Bosch products This means that failing DVR630 650 Series recorders should be returned for repair without non Bosch drives Should non Bosch hard disk drives be returned then Bosch will not ...

Page 2: ...R software In this case the current DVR settings and video will not be deleted or replaced during the update process Figure Update firmware menu 6 Select OK to begin the update process or click Cancel to stop and exit After the update process is completed you have to press OK so that the system will automatically restart Alternative a firmware upgrade can be performed via the Web Client Open Inter...

Page 3: ...mance on Mon A improved diagonal lines were more jagged than in other multiscreens Mon B image performance improved shown some flickering by certain monitor camera combinations Setting added to Auto delete video older than 3 days For some countries this is required by law SMTP port number was default on 587 when SSL is enabled o This port number is now user selectable This release includes the fol...

Page 4: ...ed user will be clearly notified when video format of DVR don t match with video format of connected cameras Improve PTZ handling in full screen you can select Menu Search Export or Exit when PTZ control is active Video playback from HDD mounted in other DVR600 possible to move complete HDD set from one to another DVR600 Avoid invalid log on when user ID is used special characters like In this fir...

Page 5: ...hich in the unlikely case of SW error triggers a restart to guarantee reliable operation throughout the units lifetime We recommend that customers update their DVR units to the newest FW to benefit from this protection layer 3 8 Version 2 0 5 File name 600series bin 2012 This release includes the following improvement Improve compatibility with Late Configuration tool version 2 7 No functional cha...

Page 6: ...in tools Internet options Security Custom level Miscellaneous Include local directory path when uploading files to a server Enable this setting to make uploading DVR400 600 firmware possible Note 3 The CC only shows maximum one event per second So if more events are generated within one second only the last event is shown On the local unit always all events are shown ...