Physical Components
3.2
RAID Controller
3.2.1 Insertion
A RAID controller should not be inserted while the
unit is powered on. Shut down before replacing a
faulty RAID controller.
Insert the RAID controller into its slot, lining up the
metal runners with the internal guides. Firmly push the
RAID controller fully into the chassis until the side
clips click into place.
3.2.2 Removal
Power down before removing a faulty
controller.
Push the controller side clips inward (towards each
other). While supporting the weight of the unit, use the
handles to pull the controller free from the unit.
3.3
Hard Drive Assemblies
3.3.1 Insertion
Align the disk carrier with an available disk slot.
Ensure that the handle is open and the carrier push
button is toward the bottom of the chassis. Push the
disk carrier until fully inserted, then close the handle
and push in the carrier button to secure the chassis in
place.
3.3.2 Removal
Do not remove a disk while in operation within a
RAID set, as this will cause the RAID set to degrade.
Only remove a disk marked as bad by the GUI and
having an amber LED illuminated beneath it. To
remove a disk, push the button on the disk carrier,
releasing the handle. Gently pull the bottom of the
handle toward you and wait for ten seconds for the
disk to stop spinning, then continue sliding the disk
out of the chassis.
Disk drives are sensitive to static electricity
and physical shock. Observe proper ESD
precautions and handle with care.