DS6R2
|
Installation and Operation Guide | 3.0 Programming
10
Bosch Security Systems, Inc. | 4/08 | F01U081960-01
Table 3: Programming Values
Program
Address Description
Factory
Default Value
Program Value
0
Master Code
1234
0001 to 9999 (0000 is not allowed)
1
User Code 1
1000
0001 to 9999 (0000 = disable)
2
User Code 2
0000
0001 to 9999 (0000 = disable)
3
User Code 3
0000
0001 to 9999 (0000 = disable)
4
Alarm Time
180
000 to 999 (0 sec to 999 sec)
5
Exit Delay Time
090
000 to 999 (0 sec to 999 sec)
6
Entry Delay time
090
000 to 999 (0 sec to 999 sec)
7
Zone 1 Type
1
2
1 = Instant
2 = Delay
2
3 = 24-hour
4 = Follower
5 = Silent zone
6 = Perimeter zone
7 = Perimeter delay zone
8
Zone 1 Bypass
3
2
1 = Bypass allowed
2 = No bypass allowed
9
Zone 1 Shunt
2
1 – Zone shunt allowed
2 = No zone shunt allowed
10
Zone 2 Type
1
4
1 = Instant
2 = Delay
2
3 = 24-hour
4 = Follower
5 = Silent zone
6 = Perimeter zone
7 = Perimeter delay zone
11
Zone 2 Bypass
3
2
1 = Bypass allowed
2 = No bypass allowed
12
Zone 2 Shunt
2
1 – Zone shunt allowed
2 = No zone shunt allowed
13
Zone 3 Type
1
1
1 = Instant
2 = Delay
2
3 = 24-hour
4 = Follower
5 = Silent zone
6 = Perimeter zone
7 = Perimeter delay zone
14
Zone 3 Bypass
3
2
1 = Bypass allowed
2 = No bypass allowed
15
Zone 3 Shunt
2
1 – Zone shunt allowed
2 = No zone shunt allowed
16
Zone 4 Type
1
1
1 = Instant
2 = Delay
2
3 = 24-hour
4 = Follower
5 = Silent zone
6 = Perimeter zone
7 = Perimeter delay zone
17
Zone 4 Bypass
3
2
1 = Bypass allowed
2 = No bypass allowed
18
Zone 4 Shunt
2
1 – Zone shunt allowed
2 = No zone shunt allowed
1
Refer to
Table 4
on page 13 for descriptions of each zone type.
2
There is only one Entry Delay Timer and one Exit Delay timer. Any zone programmed to “Delay” follows these timers.
3
If a zone is programmed to 24-hour, bypass is not allowed.